The reliability of toe systolic pressure and the toe brachial index in patients with diabetes

نویسندگان

  • Mary Romanos
  • Anita Raspovic
  • Byron Perrin
چکیده

BACKGROUND The Ankle Brachial Index is a useful clinical test for establishing blood supply to the foot. However, there are limitations to this method when conducted on people with diabetes. As an alternative to the Ankle Brachial Index, measuring Toe Systolic Pressures and the Toe Brachial Index have been recommended to assess the arterial blood supply to the foot. This study aimed to determine the intra and inter-rater reliability of the measurement of Toe Systolic Pressure and the Toe Brachial Index in patients with diabetes using a manual measurement system. METHODS This was a repeated measures, reliability study. Three raters measured Toe Systolic Pressure and the Toe Brachial Index in thirty participants with diabetes. Measurement sessions occurred on two occasions, one week apart, using a manual photoplethysmography unit (Hadeco Smartdop 45) and a standardised measurement protocol. RESULTS The mean intra-class correlation for intra-rater reliability for toe systolic pressures was 0.87 (95% LOA: -25.97 to 26.06 mmHg) and the mean intra-class correlation for Toe Brachial Indices was 0.75 (95% LOA: -0.22 to 0.28). The intra-class correlation for inter-rater reliability was 0.88 for toe systolic pressures (95% LOA: -22.91 to 29.17.mmHg) and 0.77 for Toe Brachial Indices (95% LOA: -0.21 to 0.22). CONCLUSION Despite the reasonable intra-class correlation results, the range of error (95% LOA) was broad. This raises questions regarding the reliability of using a manual sphygmomanometer and PPG for the Toe Systolic Pressure and Toe Brachial Indice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interrater and intrarater reliability of photoplethysmography for measuring toe blood pressure and toe-brachial index in people with diabetes mellitus

BACKGROUND A reliable tool to measure arterial flow to the feet in people with diabetes is required given that they are particularly prone to peripheral arterial disease. Traditionally, the ankle brachial index (ABI) has been used to measure arterial circulation, but its application is limited due to calcification of larger arteries. More recently, toe pressure and the toe brachial index (TBI) ...

متن کامل

Using the Portapres® for the measurement of toe arterial blood pressure during movement: is it valid and reliable?

The aim of the study was to assess the validity and reliability of using the Portapres® to measure toe blood pressure during rest and exercise. Construct validity, concurrent validity, and interday reliability were assessed by measuring toe (Portapres®)) and brachial blood pressure in 16 nondisabled participants on consecutive days. Construct validity was assessed by pedaling on a cycle ergomet...

متن کامل

Assessing peripheral arteries in South African black women with type 2 diabetes mellitus.

OBJECTIVES To determine the value of ankle and toe blood pressure indices and pedal pulse palpation in the assessment of peripheral arterial disease in subjects with type 2 diabetes mellitus (DM). DESIGN Cross-sectional study. SUBJECTS A convenience sample of 85 female subjects with type 2 DM underwent a series of peripheral vascular assessments at the diabetes clinic of a community hospita...

متن کامل

The Relationship between Abnormal Ankle-brachial Index and Micro-vascular Complications of Diabetes Type II

Background:The prevalence of diabetes mellitus is increasing worldwide and the relationship between peripheral vascular involvement and the complications of diabetes disease, such as retinopathy, has been reported in some studies but has not yet been fully proven. The aim of this study was to investigate the relationship between diabetes complications and peripheral and central vascular involve...

متن کامل

Utility of Toe-brachial Index for Diagnosis of Peripheral Artery Disease

BACKGROUND The ankle brachial pressure index (ABI) is a simple, useful method for diagnosing peripheral artery disease (PAD). Although the ABI is an objective diagnostic method, it has limited reliability in certain scenarios. The aim of the present study was to determine the accuracy and reliability of the toe brachial index (TBI) as a diagnostic tool for detecting stenosis in PAD, associated ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2010