Multivariate predictors of intravascular ultrasound end points after directional coronary atherectomy.

نویسندگان

  • F A Matar
  • G S Mintz
  • E Pinnow
  • S P Javier
  • J J Popma
  • K M Kent
  • L F Satler
  • A D Pichard
  • M B Leon
چکیده

OBJECTIVES This study attempted to identify the clinical, angiographic, procedural and intravascular ultrasound predictors of directional atherectomy results assessed by intravascular ultrasound. BACKGROUND Several angiographic and intravascular ultrasound variables have been associated with the outcome of directional coronary atherectomy. No study has incorporated both modalities into a predictive model. METHODS One hundred seventy patients were analyzed using preintervention and postintervention intravascular ultrasound and quantitative angiography. Clinical and procedural variables were collected by independent chart review. Quantitative and qualitative angiographic analysis was performed by a core laboratory in blinded manner. Intravascular ultrasound was performed using a transducer-tipped catheter, rotating within a stationary imaging sheath, and withdrawn automatically at 0.5 mm/s. Clinical, procedural, angiographic and ultrasound variables were tested in a multivariate linear regression model. Dependent ultrasound variables included postatherectomy lumen cross-sectional area and percent cross-sectional narrowing (plaque plus media/external elastic membrane cross-sectional area) and, in a subgroup of 47 patients studied using volumetric analysis, percent plaque volume removal. RESULTS By multivariate stepwise linear regression analysis, predictors of residual lumen cross-sectional area (correcting for reference lumen area) included arc of calcium and preatherectomy plaque plus media cross-sectional area; predictors of residual cross-sectional narrowing were arc of calcium, preatherectomy plaque plus media cross-sectional area and lesion length; and predictors of percent plaque volume removal were arc of calcium and atherectomy device size. CONCLUSIONS The preintervention lesion arc of calcium measured by intravascular ultrasound is the most consistent predictor of the effectiveness and results of directional coronary atherectomy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Plaque rupture as a cause of apparent coronary aneurysm formation following directional coronary atherectomy.

Late coronary aneurysm formation was observed following treatment by directional coronary atherectomy. Intravascular ultrasound disclosed that the mechanism involved was plaque rupture. The cause of coronary aneurysm may be multifactorial after coronary interventions. Intravascular ultrasound imaging is useful for understanding the pathologic mechanism of coronary aneurysm production.

متن کامل

Preintervention lesion remodelling aVects operative mechanisms of balloon optimised directional coronary atherectomy procedures: a volumetric study with three dimensional intravascular ultrasound

Aims—To classify atherosclerotic coronary lesions on the basis of adequate or inadequate compensatory vascular enlargement, and to examine changes in lumen, plaque, and vessel volumes during balloon optimised directional coronary atherectomy procedures in relation to the state of adaptive remodelling before the intervention. Design—29 lesion segments in 29 patients were examined with intravascu...

متن کامل

Preintervention lesion remodelling affects operative mechanisms of balloon optimised directional coronary atherectomy procedures: a volumetric study with three dimensional intravascular ultrasound.

AIMS To classify atherosclerotic coronary lesions on the basis of adequate or inadequate compensatory vascular enlargement, and to examine changes in lumen, plaque, and vessel volumes during balloon optimised directional coronary atherectomy procedures in relation to the state of adaptive remodelling before the intervention. DESIGN 29 lesion segments in 29 patients were examined with intravas...

متن کامل

Influence of plaque morphology on the mechanism of luminal enlargement after directional coronary atherectomy and balloon angioplasty.

OBJECTIVE To relate the mechanism of luminal gain after directional atherectomy and balloon angioplasty to the morphological characteristics of the coronary lesions, assessed by intravascular ultrasound imaging. DESIGN Intravascular ultrasound imaging was performed before and after the revascularisation procedure to assess the contribution of wall stretching and plaque reduction in luminal ga...

متن کامل

Clinical significance of echo signal attenuation on intravascular ultrasound in patients with coronary artery disease.

BACKGROUND Atherosclerotic plaque that shows echo signal attenuation (EA) without associated bright echoes is sometimes observed by intravascular ultrasound but its clinical significance remains unclear. We investigated the impact of EA on coronary perfusion and evaluated the pathological features of plaque with EA. METHODS AND RESULTS We studied 687 native coronary lesions in 687 consecutive...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 25 2  شماره 

صفحات  -

تاریخ انتشار 1995