Heat-treatment of bovine colostrum. II: effects of heating duration on pathogen viability and immunoglobulin G.
نویسندگان
چکیده
Batches (30-L) of first-milking bovine colostrum, inoculated with Mycoplasma bovis (10(8) cfu/mL), Listeria monocytogenes (10(6) cfu/mL), Escherichia coli O157:H7 (10(6) cfu/mL), Salmonella enteritidis (10(6) cfu/mL), and Mycobacterium avium subsp. paratuberculosis (Map; 10(3) cfu/mL), were heat-treated at 60 degrees C for 120 min in a commercial on-farm batch pasteurizer system. Duplicate 50-mL subsamples of colostrum were collected at 15-min intervals throughout the heat-treatment process for the purpose of bacterial culture and for measurement of IgG concentration (mg/mL) and antibody activity [log2(bovine viral diarrhea virus type 1 serum neutralization titer)]. Four replicate batches of colostrum were run for each of the 5 pathogens studied. There was no effect of heating moderate- to high-quality colostrum at 60 degrees C for at least 120 min on mean IgG concentration (pre = 60.5 mg/mL; post = 59.1 mg/mL). Similarly, there was no effect of heat-treatment on the mean log2 bovine viral diarrhea virus type 1 serum neutralization titer (pre = 12.3; post = 12.0). Viable M. bovis, L. monocytogenes, E. coli O157:H7, and S. enteritidis added to colostrum could not be detected after the colostrum was heat-treated at 60 degrees C for 30 min. Average bacteria counts showed that Map was not detected when batches were heated at 60 degrees C for 60 min. Although the authors believe that heat-treating colostrum at 60 degrees C for 60 min should be sufficient to eliminate Map from colostrum in most situations, further research is needed to determine whether these findings may be replicated, given that variability was observed in Map culture results.
منابع مشابه
Heat treatment of bovine colostrum. I: effects of temperature on viscosity and immunoglobulin G level.
The objective of this study was to identify the critical temperature, at or below which heat-treatment of bovine colostrum would produce no significant changes in viscosity, IgG concentration, or Ig activity. Results of preliminary work, using a Rapid Visco Analyzer (RVA) to heat 50-mL aliquots from 6 unique batches of bovine colostrum at 59, 60, 61, 62, and 63 degrees C, suggested that colostr...
متن کاملEffects of Spray-Drying, Freeze-Drying and Pasteurization on Microbiological Quality and IgG Level of Bovine Colostrum
Background: Nowadays, colostrum has been known as a considerable and valuable by-product of large-scale dairy production in the world. The main objective of this study was to evaluate the effects of pasteurization, spray-drying and freeze-drying methods on bacterial loads and Immunoglobulin G (IgG) level of bovine colostrums. Methods: Colostrum samples were collected from the first milking pos...
متن کاملRelationship between Immunoglobulin Concentrations in the Ewe's Serum and Colostrum, and Lamb's Serum in Lori-Bakhtiari Sheep
In this study 71 head of conceiving ewe and their progeny (91 head) from the flock of Lori-Bakhtiari sheep (360 head), in Sholi Station were randomly selected to determine the relationship between the immunoglobulin (IgG) concentration in the ewe's serum and colostrum, and lamb's serum. Ewe blood sample, colostrum of ewe and blood of the lamb was taken 2 weeks before parturition, 1 to 8 hours a...
متن کاملReduction in heat-induced gastrointestinal hyperpermeability in rats by bovine colostrum and goat milk powders.
Male Sprague-Dawley rats were assigned to one of three dietary groups [standard diet (Cont; n = 8), standard diet plus bovine colostrum powder (BColost 1.7 g/kg; n = 8), or goat milk powder (GMilk 1.7 g/kg; n = 8)] to determine the ability of these supplements to reduce gastrointestinal hyperpermeability induced by heat. Raising core body temperature of rats to 41.5 degrees C increased transfer...
متن کاملEffect of Heat‐treatment on Accuracy of Infrared Spectroscopy and Digital and Optical Brix Refractometers for Measuring Immunoglobulin G Concentration in Bovine Colostrum
BACKGROUND Heat-treatment of colostrum is a method developed to reduce calf exposure to pathogens. Infrared (IR) spectroscopy and Brix refractometers can be used for measuring colostral IgG concentration and assessing colostrum quality. OBJECTIVES To determine the impact of heat-treatment on accuracy of IR spectroscopy and Brix refractometers for measuring colostral IgG concentration and asse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of dairy science
دوره 89 9 شماره
صفحات -
تاریخ انتشار 2006