The effect of biomicroscope illumination system on grading anterior chamber inflammation.
نویسندگان
چکیده
PURPOSE To determine how a biomicroscope illumination system affects the grading of anterior chamber (AC) inflammation. DESIGN Laboratory investigation. METHODS An artificial AC was designed to replicate optically a human AC and was filled with 5-mum polystyrene beads suspended in ethanol. A high-definition video eyepiece camera recorded the moving beads. Using image processing software, the main outcomes measures determined were the average number of beads in a 1 x 1-mm field at varying widths of the slit-beam. RESULTS The volume of light and number of beads observed increased significantly as the slit-beam widened. Additionally, 3 separate biomicroscopes of identical make and model were found to produce different levels of luminance at the same aperture dial settings, influencing the number of beads observed, with the brighter biomicroscope yielding higher bead counts. CONCLUSIONS Ability to count beads and perhaps the ability to count inflammatory cells in an inflamed eye depend on a number of factors, including the level of illumination and width of the slit-beam. This study demonstrated that the brighter the illumination and the wider the beam, the more beads were observed. This illustrates the importance of standardizing biomicroscopy, particularly where consecutive observations are used to make clinical decisions and in cases of multicenter clinical trials where clinical data are evaluated across different facilities.
منابع مشابه
The Feasibility of Spectral-Domain Optical Coherence Tomography Grading of Anterior Chamber Inflammation in a Rabbit Model of Anterior Uveitis
PURPOSE To determine the feasibility and accuracy of spectral-domain optical coherence tomography (SD-OCT) based grading of anterior chamber cell, using aqueous sampling as a standard, in a rabbit model of anterior uveitis. METHODS Adult Dutch-belted rabbits were preimmunized with M. tuberculosis (Tb) H37RA antigen, 1 week prior to induction of anterior uveitis with an intracameral injection ...
متن کاملHigh-speed optical coherence tomography as a reliable adjuvant tool to grade ocular anterior chamber inflammation.
PURPOSE To evaluate the high-speed anterior segment optical coherence tomography (AS-OCT) grading of the AS inflammation in patients with ocular inflammation. METHODS A retrospective consecutive case series study. Patients with clinically visible AS inflammation in at least one eye underwent AS-OCT (Visante; Zeiss Meditec) with three to eight line scans per eye, performed by a trained masked ...
متن کاملThe Role of Immune System in Idiopathic Anterior Uveitis
Background: Idiopathic anterior uveitis is an anterior segment inflammation in which a detailed medical history, general and ocular physical examination is not associated with any defined clinical syndrome. Alterations in immune system parameters have been reported in patients with idiopathic posterior uveitis; however no data on the role of immune system in idiopathic anterior uveitis has yet ...
متن کاملمقایسه قطره دیکلوفناک سدیم با قطره بتامتازون در پیشگیری از ادم سیستویید ماکولا، پس از جراحی کاتاراکت به روش خارج کپسولی با لنز گذاری
Background and purpose: Since Çystoid Macular Ëdema (ÇMË) is caused by ocular inflammation after cataract surgery. Ït’s control with suitable medication is reasonable. Âim of this study was to compare a nonsteroidal topical solution (0.1 % diclofenac) to a steroidal topical solution (0.1 % betamethasone) in preventing ÇMË after extra capsular cataract surgery. Materials and methods: Â pro...
متن کاملNoncontact Screening Methods for the Detection of Narrow Anterior Chamber Angles.
PURPOSE Comparing diagnostic accuracy of biomicroscope techniques (van Herick and Smith's tests, evaluating limbal and central anterior chamber depth, respectively) and advanced imaging (Visante OCT and Pentacam) for detection of gonioscopically narrow anterior chamber angles (ACAs). METHODS A total of 78 subjects with narrow or open ACAs underwent four index tests, performed on both eyes by ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of ophthalmology
دوره 148 4 شماره
صفحات -
تاریخ انتشار 2009