We thank Onder Ayyildiz and GokhanOzge for their interest and comment on our paper “The Effects of Hemodialysis on Tear Osmolarity” [1, 2]. They thought that detection of TO would be performed at the same time of the day regarding the duration of hemodialysis (HD) which may avoid the bias of the methodology according to the study of Niimi et al. [3]. Niimi et al. have enrolled 38medically healthy neophytes. Their subjects reported to theCRCan average of 14±2.0hours (7–17 hours) after awakening for baseline measurements and sleeping at the CRC, thereby allowing for uniform environmental exposure (e.g., humidity and temperature) and timely collection of measurements upon awakening. The physical conditions of our clinic are not suitable for all HD patients to report 7 hours after awakening for baseline measurements and sleeping one day thereby allowing for uniform environmental exposure (e.g., humidity and temperature) and timely collection of measurements upon awakening. In our Hemodialysis Unit, two HD sessions have been performed; the first session was between 8:30 and 12:30 and the second session was between 13:00 and 17:00. 23 patients were in the first session and 20 patients were in the second session in our study. Tear osmolarity (TO) measurements have been performed oneminute before the beginning of HD Table 1: Pre-HD and post-HD tear osmolarity according to HD sessions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effects of Hemodialysis on Tear Osmolarity

Aim. To determine the effects of hemodialysis (HD) on tear osmolarity and to define the blood biochemical tests correlating with tear osmolarity among patients with end stage renal disease (ESRD). Material-Method. Tear osmolarity of ESRD patients before and after the hemodialysis program was determined as well as the blood biochemical data including glucose, sodium, potassium, calcium, urea, an...

متن کامل

Comprehensive evaluation of dehydration impact on ocular tissue during Ramadan fasting

Purpose: The present study aimed to review the effect of dehydration during Ramadan fasting on the health and ocular parameters leading to changes in eye function. Methods: Articles included in the study were taken from Pub Med, Ovid, Web of Science and Google Scholar up to 2014.Related articles were also obtained from scientific journals in fasting and eye. Results: Dehydration and nutrition c...

متن کامل

The Effects of Intense Pulsed Light on Tear Osmolarity in Dry Eye Disease

Purpose: In this prospective study we show the influence of Intense Pulsed Light Therapy (IPL) on tear osmolarity, an increasingly important metric of dry eye disease. Previous studies have measured the effectiveness IPL has had on other metrics including tear break up time (TBUT), lipid layer grade (LLG), tear evaporation rate (TER), tear meniscus height (TMH), and subjective responses from pa...

متن کامل

What is the value of incorporating tear osmolarity measurement in assessing patient response to therapy in dry eye disease?

PURPOSE To evaluate the correlation between changes in tear osmolarity, symptoms, and corneal fluorescein staining in patients with dry eye disease (DED). DESIGN Retrospective, clinic-based cohort study. METHODS In this single-institution study, we reviewed the charts of 186 patients with DED from whom we had data on tear osmolarity, symptoms, and corneal fluorescein staining from 2 separat...

متن کامل

The Effects of Hot Tear Segregations on the Rolled Product Quality of Continuously Cast Steel

The main objective of this project was to investigate the behavior and the damaging effects of hot tear segregations in the continuously cast steel blooms on the final product quality. To achieve this aim, plant data from three different types of steels were used. Investigations using the scanning electron microscope (SEM) equipped with energy dispersive x-ray spectroscopy (EDS) probe and metal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016