Regional seismic hazard for Revithoussa, Greece: an earthquake early warning Shield and selection of alert signals

نویسندگان

  • Y. Xu
  • P. W. Burton
چکیده

The feasibility of an earthquake early warning Shield in Greece is being explored as a European demonstration project. This will be the first early warning system in Europe. The island of Revithoussa is a liquid natural gas storage facility near Athens from which a pipeline runs to a gas distribution centre in Athens. The Shield is being centred on these facilities. The purpose here is to analyze seismicity and seismic hazard in relation to the Shield centre and the remote sensor sites in the Shield network, eventually to help characterize the hazard levels, seismic signals and ground vibration levels that might be observed or create an alert situation at a station. Thus this paper mainly gives estimation of local seismic hazard in the regional working area of Revithoussa by studying extreme peak ground acceleration (PGA) and magnitudes. Within the Shield region, the most important zone to be detected is WNW from the Shield centre and is at a relatively short distance (50 km or less), the Gulf of Corinth (active normal faults) region. This is the critical zone for early warning of strong ground shaking. A second key region of seismicity is at an intermediate distance (100 km or more) from the centre, the Hellenic seismic zone south or southeast from Peloponnisos. A third region to be detected would be the northeastern region from the centre and is at a relatively long distance (about 150 km), Lemnos Island and neighboring region. Several parameters are estimated to characterize the seismicity and hazard. These include: the 50-year PGA with 90% probability of not being exceeded (pnbe) using Theodulidis & Papazachos strong motion attenuation for Greece, PGANTP; the 50-year magnitude and also at the 90% pnbe, M50 and MP50, respectively. There are also estimates of the earthquake that is most likely to be felt at a damaging intensity level, these are the most perceptible earthquakes at intensities VI, VII and VIII with magnitudes MVI, MVII and MVIII. Example results (from many) include the corresponding parameters describing the hazard for Revithoussa as follows: PGANTP: 203 cm s−2, M50: 6.5, Mp50: 6.9, MVI: 5.8, Correspondence to: Y. Xu ([email protected]) MVII: 6.1 and MVIII: 6.4. These data are also useful in selecting expected alert-signals i.e. examples of strong ground vibration histories that might be expected at a Shield station in the alert situation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

How Well Can We Extract the Permanent Displacement from Low-Cost MEMS Accelerometers?

Following the recent establishment of a high-density seismic network equipped with low-cost micro-electro-mechanical system (MEMS) P-wave-alert-device (P-Alert) by the earthquake early warning (EEW) research group at the National Taiwan University, a large quantity of strong-motion records from moderate-magnitude earthquakes (ML > 6) around Taiwan has been accumulated. Using a data preprocessin...

متن کامل

Earthquake Early Warning System Based on Multiple Sensor Network

Earthquake is one of the major natural calamity. So prediction of the reach of earthquake event to the various locations could result in minimizing the disaster due to it. This system contains the design of sensor system and the techniques used for detection and processing of the received signals in real time. In this system, an earthquake which is also known as a tremor or temblor is the resul...

متن کامل

تحلیل دینامیکی غیرخطی هندسی سدهای بتنی قوسی

 This paper presents an assessment of the seismic hazard for the Markazi province. For approch to this aim based on Seismotectonic conditions, regional earthquake dam and seismicity analyses the active faults and potential seismic sources of the region are identified and illustrated in a seismotectonic map. By useing different thechniques such as “Time Normalization” a model of earthquake sourc...

متن کامل

The Earthquake Early Warning System in southern Italy: Technologies, Methods and Performance Evaluation

A real-time seismic monitoring infrastructure has been recently installed and it is actually operating in southern Italy, whose main purposes are to rapidly issue an earthquake alert, to provide near-real-time maps of the peak ground motion and intensity shaking and to test the feasibility of earthquake early warning following moderate to large earthquakes occurring along the southern Apenninic...

متن کامل

Evaluating and Improving the ElarmS Earthquake Early Warning Algorithm

Earthquake Alarm Systems, or ElarmS, is a network-based earthquake early warning (EEW) system developed in California. This dissertation concerns the transition of ElarmS from research prototype to production-grade code. We test ElarmS' performance for large earthquakes with an extensive dataset of large events from Japan. Using the Japanese dataset and results, we develop a statistical error m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003