BACKGROUND Silicone rod is a commonly used synthetic suspension material in frontalis suspension surgery to correct blepharoptosis. The most challenging problem and a decisive drawback of the use of silicone rod is a considerable rate of ptosis recurrence after surgery. We examined patients with recurred ptosis and assessed the physical and micromorphological properties of implanted silicone rods to determine the causative mechanisms of recurred ptosis after frontalis suspension using silicone rod. METHODS This is a prospective observational case series of 22 pediatric patients with recurred ptosis after frontalis suspension using silicone rods for congenital ptosis. Implanted silicone rods were observed and removed during the operation for correction of recurred ptosis. The removed silicone rods were physically and micromorphologically evaluated to determine the cause of recurrence. RESULTS Pretarsal fixation positions migrated upward, whereas suprabrow fixation positions migrated downward during ptosis recurrence. The breaking strength of implanted silicone rods was reduced by approximately 50% during 3 years. Cracks, debris, and loss of homogenous structure with disintegration were observed on scanning electron micrographs of implanted silicone rods in patients with recurred ptosis. Preoperative severe degree of ptosis also contributed to recurred ptosis. CONCLUSIONS Recurrence of ptosis after frontalis suspension using silicone rod was associated with physical changes of implanted silicone rods, including positional migration, weakened tensile strength, and micromorphological changes in combination with patients' characteristics.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cosmetic and functional outcomes of frontalis suspension surgery using autologous fascia lata or silicone rods in pediatric congenital ptosis

PURPOSE Cosmetic and functional outcomes of frontalis suspension surgery using autologous fascia lata (FL) or silicone rods (SRs) in pediatric congenital ptosis. DESIGN Retrospective case series. STUDY SUBJECTS Patients with congenital ptosis, aged 18 years or younger, during the period under study (2005-2011) at the Singapore National Eye Centre. METHODS Review of case records for functi...

متن کامل

The Impact of Silicone Frontalis Suspension with Ptosis Probe R for the Correction of Congential ptosis on the Asian Eyelids in Taiwan

To evaluate the basic technique of Ptosis probe R and the impact of ptosis repair by silicone rod frontalis sling on the Asian eyelid. A retrospective interventional study including 30 patients (49 eyelids) who underwent silicone rod frontalis suspension by the same surgeon between 2005 and 2008. Cosmetic outcomes , marginal reflex distance (MRD), chin-up head posture and recurrence rate were e...

متن کامل

The Long-Term Results of Frontalis Suspension Using Autogenous Fascia Lata in Children with Congenital Ptosis under 3 Years Old

Purpose. To describe the long-term results of frontalis suspension using autogenous fascia lata in children with congenital ptosis under 3 years old. Methods. Forty three-eyes of 35 patients were enrolled in the study. Frontalis suspension using autogenous fascia lata was performed in all patients. The postoperative eyelid level, ptosis recurrence, visual acuity, and cosmetic results were evalu...

متن کامل

Frontalis Sling Operation using Silicone Rod Compared with Autogenous Fascia Lata for Simple Congenital Ptosis.

INTRODUCTION To evaluate the cosmetic results and recurrence of unilateral frontalis sling surgery using a silicone rod compared with autogenous fascia lata in cases of simple congenital ptosis. METHODS This is a retrospective comparative study of 59 patients who underwent a frontalis sling operation for congenital ptosis. Patients were divided into two groups according to the sling material ...

متن کامل

Five-Year Follow-Up of a 30-Month Trial of Stability of Silicone Band Frontalis Suspension for the Treatment of Severe Unilateral Upper Eyelid Ptosis in Infants.

PURPOSE To evaluate the five-year stability of frontalis suspension of the upper eyelid with a silicone band for the treatment of severe congenital ptosis in infants. METHODS Chart review of pediatric patients with a follow-up of five years after unilateral frontalis suspension with silicone band was reviewed. Margin-reflex distance (MRD) and corneal staining were measured at different follow...