New spatiotemporal approaches for fully refocused, multislice ultrafast 2D MRI.

نویسندگان

  • Rita Schmidt
  • Lucio Frydman
چکیده

PURPOSE Single-scan multislice acquisition schemes play key roles in magnetic resonance imaging. Central among these "ultrafast" experiments stands echo-planar imaging, a technique that although of optimal sampling is challenged by T2* artifacts. Recent studies described alternatives based on spatiotemporal encoding (SPEN), which are particularly robust if implemented in a "full-refocusing" mode. This work extends this modality from the single-slice acquisitions in which it has hitherto been implemented, by introducing a variety of multislice schemes scanning 3D volumes. METHODS Multislice SPEN employing either inversion or stimulated echo pulses and timed to fulfill the demands of full refocusing, are demonstrated. The performance of the ensuing methods was examined in "Hybrid" modalities encoding data in k- and direct-space, in low-specific absorption rate stimulated-echo approaches, and in direct-space SPEN approaches. RESULTS When applied in phantoms and in in vivo systems, the ensuing single-shot sequences evidenced similar robustness, sensitivity, and resolution qualities as previously discussed 2D single-slice schemes, while enabling a rapid sampling of the third dimension via multislicing. CONCLUSION The unique benefits deriving from fully refocused, multislice, single-scan SPEN sequences were corroborated by phantom tests, as well as by in vivo scans at 3 and 7 T. Low specific absorption rate multislice SPEN variants compatible with human studies were demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Helical MR: continuously moving table axial imaging with radial acquisitions.

A technique for extended field of view MRI is presented. Similar to helical computed tomography, the method utilizes a continuously moving patient table, a 2D axial slice that remains fixed relative to the MRI magnet, and a radial k-space trajectory. A fully refocused SSFP acquisition enables spatial resolution comparable to current clinical protocols in scan times that are sufficiently short t...

متن کامل

2D multislice and 3D MRI sequences are often equally sensitive.

A simple theoretical model was developed to compare the sensitivities (i.e., signal-to-noise ratios per unit imaging time) of two-dimensional (2D) multislice and 3D imaging sequences. The model shows that the sensitivities of 3D and 2D multislice MRI sequences are usually similar. Sensitivities are identical in T2-weighted sequences when the T(R)s of the two sequences are the same. In T1-weight...

متن کامل

Spatiotemporal encoding as a robust basis for fast three-dimensional in vivo MRI.

Recent studies have described some of the new opportunities that have arisen within the context of ultrafast two-dimensional imaging with the advent of spatiotemporal encoding methods. This article explores the potential of integrating these non-Fourier, single-scan, two-dimensional MRI principles, with multi-slice and phase-encoding schemes acting along a third dimension. In unison, these comb...

متن کامل

In vivo 3D spatial/1D spectral imaging by spatiotemporal encoding: a new single-shot experimental and processing approach.

A novel method for acquiring and processing quality multislice spectroscopically resolved 2D images in a single shot is introduced and illustrated. By contrast to the majority of single-scan spectroscopic imaging sequences developed so far, the method here discussed is not based on the acquisition of echo planar data in the k/t-space, but rather on the use of recently proposed spatiotemporal en...

متن کامل

Super-resolved parallel MRI by spatiotemporal encoding.

Recent studies described an "ultrafast" scanning method based on spatiotemporal (SPEN) principles. SPEN demonstrates numerous potential advantages over EPI-based alternatives, at no additional expense in experimental complexity. An important aspect that SPEN still needs to achieve for providing a competitive ultrafast MRI acquisition alternative, entails exploiting parallel imaging algorithms w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 71 2  شماره 

صفحات  -

تاریخ انتشار 2014