Comparison of the fluorescent treponemal antibody absorption (FTA-ABS) test with the FTA-ABS double staining test for detection of antitreponemal immunoglobulin M in the 19S fraction of human serum.

نویسندگان

  • G Ozanne
  • M A d'Halewyn
  • S A Larsen
چکیده

A widely used immunoglobulin M (IgM) detection assay for the diagnosis of neonatal congenital syphilis is the fluorescent treponemal antibody absorption test used with fractionated serum (FTA-ABS 19S IgM test). Reading the results of the FTA-ABS test is more cumbersome than reading those of the FTA-ABS double staining (FTA-ABS-DS) test, a confirmatory test for specific IgG. To verify that the FTA-ABS-DS test used with an anti-human IgM conjugate could detect specific IgM in fractionated serum samples (FTA-ABS-DS 19S IgM test), 164 fractionated (QUIK-SEP IgM Isolation System; ISOLAB, Inc., Akron, Ohio) serum specimens from infected neonates or adults or from IgG-seronegative subjects were tested by both techniques. The sensitivity limits of the two tests were assessed with reactive serum samples diluted to an endpoint titer. Samples nonreactive by the FTA-ABS 19S IgM test (n = 74) were either nonreactive (n = 65), minimally reactive (n = 5), or reactive (n = 4) by the FTA-ABS-DS 19S IgM test. Samples minimally reactive by the FTA-ABS 19S IgM test (n = 32) were minimally reactive (n = 1) or reactive (n = 31) by the double staining test. All samples reactive by the FTA-ABS 19S IgM test (n = 58) were also reactive by the FTA-ABS-DS 19S IgM test. There was a directly proportional linear relationship (r = 0.9794) between titers obtained by both tests. FTA-ABS-DS 19S IgM titers were constantly equal to or higher than FTA-ABS 19S IgM titers. Fluorescence intensity reading repeatability was 91.4% for the FTA-ABS-DS 19S IgM test and 81.7% for the FTA-ABS 19S IgM test (P = 0.015). Because the more easily read FTA-ABS-DS 19S IgM test is at least as sensitive as, if not more sensitive than, the FTA-ABS 19S IgM test, it is a good alternative to the latter test for the detection of specific IgM in human fractionated sera for those using fluorescence microscopes with incident light.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Double-staining procedure for the fluorescent treponemal antibody absorption (FTA-ABS) test.

The fluorescent treponemal antibody absorption (FTA-ABS) double-staining procedure was reproducible, comparable to the conventional test, and easy to read. We recommend the use of the FTA-ABS double-staining procedure for microscopes with incident illumination, the 100 x/1.30 oil achromatic objective and the 6.3 x ocular to obtain optimal fluorescence, and the KP560 as a barrier filter to exclu...

متن کامل

Fluorescent treponemal antibody absorption double-staining test evaluation.

The fluorescent treponemal antibody absorption (FTA-ABS) double-staining (DS) test has been developed for microscopes equipped with incident illumination, and the procedure offers many advantages over the FTA-ABS test when tests are performed with this equipment. In this study, 346 fresh sera, including 35 from patients with syphilis, were evaluated by the FTA-ABS DS test. Parameters for invest...

متن کامل

IgM class antitreponemal antibody in treated and untreated syphilis.

It is a particular advantage of the indirect fluorescent antibody (IFA) method that antibodies of different immunoglobulin classes may be separately detected and measured by the use of monospecific antiglobulin conjugates. Matuhasi, Mizuoka, and Usui (1966), Kiraly, Bachhausz, Jobbagy, Lajos, and Kovats (1968), Julian, Logan, and Norins (1969), and Atwood and Miller (1969) studied antibodies in...

متن کامل

Evaluation of a new competitive immunoassay (BioElisa Syphilis) for screening for Treponema pallidum antibodies at various stages of syphilis.

The BioElisa Syphilis, a new competitive enzyme immunoassay (EIA) for Treponema pallidum whole antigen that uses specific human immunoglobulin G (IgG) antibodies as the competitor, was evaluated for potential use in screening for syphilis at various stages. The results obtained by this competitive EIA were compared with those obtained by the fluorescent treponemal antibody absorption (FTA-abs) ...

متن کامل

Evaluation of a fully automated treponemal test and comparison with conventional VDRL and FTA-ABS tests.

We evaluated analytic performances of an automated treponemal test and compared this test with the Venereal Disease Research Laboratory test (VDRL) and fluorescent treponemal antibody absorption test (FTA-ABS). Precision performance of the Architect Syphilis TP assay (TP; Abbott Japan, Tokyo, Japan) was assessed, and 150 serum samples were assayed with the TP before and after heat inactivation ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 31 1  شماره 

صفحات  -

تاریخ انتشار 1993