Developing a Sensing System for the Measurement of Oxygen Concentration in Liquid Pb-Bi Eutectic

نویسندگان

  • Yingtao Jiang
  • Bingmei Fu
  • Woosoon Yim
  • Y. Jiang
  • W. Yim
چکیده

Although liquid lead-bismuth eutectic (LBE) is a good candidate for the coolant that can be employed in a subcritical transmutation blanket, it is known to be very corrosive to stainless steel, the material used in the containment structure. To mitigate this problem, trace levels of oxygen can be introduced into the system, causing the formation of a protective oxide layer at the interface between the LBE and steel. The proper formation of this oxide layer largely depends on the accurate measurement and subsequent control of the oxygen concentration in liquid LBE.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calibration of YSZ Sensors for the Measurement of Oxygen Concentration in Liquid Pb-Bi Eutectic

Although liquid lead-bismuth eutectic (LBE) is a good candidate for coolant in the subcritical transmutation blanket, it is known to be corrosive to stainless steel, the material of the carrying tubes and containers. Such longterm corrosion problem can be prevented by producing and maintaining a protective oxide layer on the exposed surface of stainless steel. For this purpose, it is required t...

متن کامل

Critical temperature of the lead–bismuth eutectic (LBE) alloy

Liquid metals such as Bi and Pb and Pb–Bi eutectic alloy are serious contenders for use as coolant in LMFBRs in lieu of sodium due to a number of attractive characteristics (high density, low moderation, low neutron absorption and activation, high boiling point and poor interaction with water and air, etc.). Analysis of hypothetical accidents is of relevance to predict the catastrophe involving...

متن کامل

Optimization of a SPECT system for imaging of 90Y in liver using Monte Carlo method

Introduction: Acquiring a high quality image has assigned an important concern for obtaining accurate diagnosis in nuclear medicine. Detector and collimator are critical component of Single Photon Emission Computed Tomography (SPECT) imaging system for giving accurate information from exact pattern of radionuclide distribution in the target organ. The images are strongly affect...

متن کامل

Handbook on Lead-bismuth Eutectic Alloy and Lead Properties, Materials Compatibility, Thermal-hydraulics and Technologies

3.2 Enthalpies, entropies (solid and liquid state) – free energy and entropy of mixing The heats of formation of six solid Pb-Bi alloys have been measured at 400 K in a liquid lead solution calorimeter by P. Roy, et al. They found that these alloys obey Kopp’s law of additivity and the heats of formation are therefore temperature independent. The lead and bismuth used in these experiments were ...

متن کامل

Instrumentation of Ysz Oyxgen Sensor Calibration in Lead-bismuth Eutectic

Although liquid lead-bismuth eutectic (LBE) is a good candidate for the coolant in the subcritical transmutation blanket, it is also known to be very corrosive to stainless steel, the material of the carrying tubes and the containers. Such a corrosion problem can be prevented by producing and maintaining a protective oxide layer on the exposed surface of stainless steel. Proper formation of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008