Measurements of Strontium-90 in portuguese milk samples using liquid scintillation counting technique

نویسندگان

  • I. Lopes
  • M. J. Madruga
چکیده

The objective of this study is the implementation of a method combining extraction chromatography and liquid scintillation counting (LSC) technique to the determination of 90Sr in milk samples. The strontium separation is performed using the commercially available Sr-resin (Eichrom) and the beta counting is carried out using a liquid scintillation detector system (Tri-Carb 3170 TR/SL, Packard). Firstly, the trials are performed with 300mL of milk and 0.7 g of resin. Validation trials are carried out using spiked milk samples with different 90Sr activities and the accuracy of the methodology is also been tested with an IAEA 152 reference milk sample. The results obtained had shown good accuracy of expected value. The minimum detectable activity (MDA) obtained for a confidence level of 95% and 60 minutes of sample counting time was 0.20BqL−1. In order to improve the detection limits for 90Sr, 1 liter of milk and 3 g of resin were used and the MDA value in these conditions was improved to 0.012BqL−1. The method was applied to the determination of the 90Sr concentrations in milk samples from different regions of Portugal.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid method for determination of 90Sr in seawater by liquid scintillation counting with an extractive scintillator.

A rapid determination method of 90Sr is developed for the monitoring of seawater around the Fukushima Daiichi Nuclear Power Plant (FDNPP). Three ideas of chemical separation and measurements to accelerate 90Sr analysis are investigated. Strontium is co-precipitated in a two-step procedure with hydroxyapatite after the removal of magnesium phosphate in the presence of citric acid. The purificati...

متن کامل

Measurement of Strontium-90 in the Persian Gulf Fish by Extraction Chromatography with Sr-resin and Liquid Scintillation Counter

Background: Despite its beneficial effects on human life, the nuclear industry has its own risks. Strontium 90 (90Sr) is one of the most dangerous radionuclides produced by the uranium 235 fission, and replaces the bone calcium in the human body, which causes cancer. Ensuring the safety of nuclear facilities to protect employees, people and the environment is among the main goals of nuclear saf...

متن کامل

Survey on the presence of Sr in milk samples by a validated ultra low level liquid scintillation counting (LSC) method

Sr is one of the most biologically hazardous radionuclides produced in nuclear fission processes and decays emitting high-energy beta particles turning Y. Sr is transferred from soil-plant to cow’s milk and then to humans if it is introduced into the environment. Radiostrontium is chemically similar to calcium entering the human body through several food chains and depositing in bone and blood-...

متن کامل

Simultaneous measurement of 89Sr and 90Sr in aqueous samples by liquid scintillation counting using the spectrum unfolding method.

Two radiostrontium isotopes, 89Sr and 90Sr, were measured simultaneously by liquid scintillation counter coupling with a full spectrum DPM counting protocol. Strontium was separated from the aqueous media by extraction chromatography using Sr-spec resin. Individual count rates were evaluated from quench correlation curves for 89Sr and 90Sr related with SIS and tSIE quench indicators. The method...

متن کامل

Synthesis and Characterization of γ-MnO2-AgA Zeolite Nanocomposite and its Application for the Removal of Radioactive Strontium-90 (90Sr)

In this scientific research, for the first time, the removal of radioactive strontium-90 (90Sr) by γ-MnO2-AgA zeolite as a novel nanocomposite adsorbent was accomplished under different conditions such as pH, temperature, adsorbent amount and the contact time that are examined from drinking water of Ramsar city and monitored via Ultra Low-Level Liquid Scintillation Counting (LSC) technique. Pri...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008