Acute polyethylene fracture in an uncemented acetabular cup.

نویسندگان

  • A E Gross
  • W N Dust
چکیده

The smaller acetabular components used in total hip replacement may have a polyethylene liner that is too thin, resulting in higher polyethylene stress and an increased potential for wear. The authors present a case that highlights the problem of acute polyethylene fracture. To compensate for the thinness of the polyethylene, the authors recommend the use of a smaller head size to allow polyethylene thickness of at least 8 mm.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Catastrophic failure of the polyethylene liner of uncemented acetabular components.

Ten cases are described of catastrophic failure of the polyethylene liner of three different designs of uncemented acetabular component. Failure occurred as a result of either 'wearthrough' to the metal backing, liner fracture or a combination of both, at a mean of 4.6 years after implantation (2 to 7.6). At revision there was metallosis in all hips and osteolysis of the femur or the pelvis in ...

متن کامل

Clinical and radiological outcome following total hip arthroplasty with an uncemented trabecular metal monoblock acetabular cup.

Uncemented acetabular components are associated with a significant incidence of polyethylene wear and secondary osteolysis. The new tantalum/polyethylene composite (Hedrocel) acetabular component is designed to reduce the polyethylene wear and to increase the longevity of the acetabular cups. We report our short- term clinical outcome and patient satisfaction following use of an uncemented tant...

متن کامل

Polyethylene wear in cemented metal-backed acetabular cups.

We examined radiographic polyethylene wear in 233 cemented total hip arthroplasties (201 patients) with either a metal-backed or a non-metal-backed acetabular cup. All patients had identical cemented one-piece titanium femoral stems with a femoral head diameter of 28 mm. The mean linear wear rate was 0.11 mm/yr in metal-backed sockets and 0.08 mm/yr in non-metal-backed sockets (p = 0.0002). The...

متن کامل

Polyethylene wear in uncemented acetabular components.

We measured polyethylene wear in 231 porous-coated uncemented acetabular cups. We divided the hips into two groups according to the fixation of the femoral component, by cementing (n = 97) or press-fit (n = 134). Follow-up was from three to five years. The patients in two sub-groups were matched for weight, diagnosis, sex, age and length of follow-up. The linear wear rate of cups articulated wi...

متن کامل

Comparison of acetabular reamings during hip resurfacing versus uncemented total hip arthroplasty.

PURPOSE To compare the quantity of bone removed from the acetabulum during resurfacing hip arthroplasty versus uncemented total hip arthroplasty (THA). METHODS 62 consecutive patients with osteoarthritis of the hip were prospectively studied. 24 men and 7 women aged 40 to 86 (mean, 59) years underwent Birmingham hip resurfacing. 13 men and 18 women aged 34 to 88 (mean, 61) years underwent unc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Canadian journal of surgery. Journal canadien de chirurgie

دوره 40 4  شماره 

صفحات  -

تاریخ انتشار 1997