Scatter correction by two-window method standardizes cardiac I-123 MIBG uptake in various gamma camera systems.

نویسندگان

  • Hideki Kobayashi
  • Mitsuru Momose
  • Shinichi Kanaya
  • Chisato Kondo
  • Kiyoko Kusakabe
  • Norio Mitsuhashi
چکیده

UNLABELLED Heart to mediastinum count ratio (H/M) has been commonly utilized as an indicator of myocardial I-123 MIBG uptake. However, normal ranges of H/M were markedly different among various gamma camera systems. The purpose of this study was to clarify whether scatter correction by two-window method standardizes H/M among various gamma camera systems. METHODS Scatter uncorrected and corrected MIBG imaging was acquired in phantom and human studies in combination with low energy high-resolution collimator (LEHR) and medium energy collimator (MEC). For scatter correction, energy window width of 159 keV +/- 10% was applied to main window imaging and 193 keV +/- 9.5% was applied to upper window imaging for scatter correction. RESULTS In phantom study, a significant difference was observed in uncorrected H/M among three gamma camera systems using LEHR or MEC (2.09 +/- 0.06 vs. 2.58 +/- 0.03 in GCA7200 camera, 2.00 +/- 0.07 vs. 2.42 +/- 0.06 in DS7 camera and 2.16 +/- 0.04 vs. 2.67 +/- 0.07 in Vertex plus camera). However, there was no significant difference in corrected H/M among the three gamma camera systems, either with LEHR or MEC (2.70 +/- 0.07 vs. 2.69 +/- 0.07 in GCA7200 camera, 2.66 +/- 0.08 vs. 2.61 +/- 0.05 in DS7 camera and 2.66 +/- 0.05 vs. 2.61 +/- 0.05 in Vertex plus camera). In human study, uncorrected H/M in DS7 camera with LEHC was significantly lower than that in GCA7200 camera with MEC (1.60 +/- 0.37 vs. 1.85 +/- 0.54, N = 14). In contrast, the difference was insignificant in corrected H/M (2.12 +/- 0.59 vs. 2.16 +/- 0.68). There was a very excellent correlation in corrected H/M between DS7 and GCA7200 cameras (r = 0.991, p < 0.001). CONCLUSION This study demonstrated that scatter correction by the two-window method standardizes the H/M in MIBG scintigraphy either with LEHR or MEC. Scatter corrected H/M can be applied to measure a standardized parameter of MIBG uptake in human clinical studies using various gamma camera systems.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Appropriate energy window width for gamma camera [Persian]

Introduction: Scatter radiation is one of the major sources of error in nuclear medicine data processing. Different methods of scatter correction have been introduced in order to improve the quality of data. However the best method is to avoid recording of scatter photons in acquisition. The only difference between scattered and non-scattered photons is the energy. Pulse height analyzer i...

متن کامل

A new method for crosstalk correction in simultaneous dual-isotope myocardial imaging with Tl-201 and I-123.

We have developed a new method of crosstalk correction in simultaneous dual-isotope imaging with Tl-201 and I-123 by using crosstalk ratios and a blurring filter. Single isotope myocardial studies (10 for Tl-201 and 7 for I-123) were performed with a dual energy window acquisition mode and two low energy general-purpose collimators. Then two planar images acquired with dual energy windows for a...

متن کامل

Standardization of the heart-to-mediastinum ratio of iodine-123-labeled-meta-iodobenzylguanidine uptake using dual energy window method: Feasibility of correction from different camera-collimator combinations

Background. Although heart-to-mediastinum (H/M) ratio in a planner image has been used for practical quantification for I-metaiodobenzylguanidine (MIBG) imaging, standardization of the parameter is not yet established. We hypothesized that the value of H/M can be standardized to the various types of camera-collimator combinations. Methods and Results. Standard phantoms consisting of the heart, ...

متن کامل

Simulation and patient studies of scatter correction in cardiac SPECT imaging

Introduction: Myocardial perfusion imaging is a nuclear medicine imaging method that is used to detect coronary artery diseases. One of the main sources of error in this imaging method is the detection of Compton scattered photons in the photopeak energy window used for data acquisition. This results in the degradation of the image contrast, and therefore decreases the...

متن کامل

A camera based calculation of 99mTc-MAG3 clearance using conjugate views method [Persian]

Background: Measurement of absolute or differential renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods in approximation of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of nuclear medicine

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2003