Biventricular pacing decreases sympathetic activity compared with right ventricular pacing in patients with depressed ejection fraction.
نویسندگان
چکیده
BACKGROUND Although there have been few studies in which the hemodynamic effects of right ventricular (RV) and left ventricular (LV) pacing were compared with those of biventricular (BV) pacing, the autonomic changes during these different pacing modes remain unknown. We hypothesized that BV pacing results in improved hemodynamics and a decrease in sympathetic nerve activity (SNA) compared with single-site pacing. METHODS AND RESULTS Thirteen men with a mean ejection fraction of 0.28+/-0.7 were enrolled in the study. Arterial blood pressure (BP), central venous pressure (CVP), and SNA were recorded during 3 minutes of right atrial (RA)-RV, RA-LV, and RA-BV pacing at a rate 10 beats faster than sinus rhythm. BP was greater during LV (151+/-7/85+/-3 mm Hg) and BV (151+/-6/85+/-3 mm Hg) pacing than during RV pacing (146+/-7/82+/-3 mm Hg) (P:<0.05). There were no differences in CVP among all pacing modes (P:=0.27). SNA was significantly less (P:<0.02) during both LV (606+/-35 U) and BV (582+/-41 U) pacing compared with RV pacing (685+/-32 U) (P:<0.02). Although not statistically significant (P:=0. 08 to 0.14), there was a trend for patients with a narrow QRS to have a lower mean BP and higher SNA during LV pacing than during BV pacing (r=0.42 to 0.49). CONCLUSIONS LV-based pacing results in improved hemodynamics and a decrease in SNA compared with RV pacing in patients with LV dysfunction regardless of the QRS duration.
منابع مشابه
Biventricular pacing in patients with bradycardia and normal ejection fraction.
BACKGROUND Observational studies suggest that conventional right ventricular apical pacing may have a deleterious effect on left ventricular function. In this study, we examined whether biventricular pacing is superior to right ventricular apical pacing in preventing deterioration of left ventricular systolic function and cardiac remodeling in patients with bradycardia and a normal ejection fra...
متن کاملTemporary epicardial left ventricular and biventricular pacing improves cardiac output after cardiopulmonary bypass
BACKGROUND To evaluate, with different pacing modes, acute changes in left ventricular systolic function, obtained by continuous cardiac output thermodilution in various subsets of patients undergoing cardiopulmonary bypass surgery. Increments of mean arterial pressure and cardiac output were considered the end point. METHODS Fifty cases electively submitted to cardiac surgery were analyzed. ...
متن کاملBiventricular pacing for atrioventricular block and systolic dysfunction.
BACKGROUND Right ventricular pacing restores an adequate heart rate in patients with atrioventricular block, but high percentages of right ventricular apical pacing may promote left ventricular systolic dysfunction. We evaluated whether biventricular pacing might reduce mortality, morbidity, and adverse left ventricular remodeling in such patients. METHODS We enrolled patients who had indicat...
متن کاملImproving cardiac function after cardiac surgery by biventricular pacing in patient selected by three-dimensional echocardiography.
We present the case of a 57-year-old woman with severe aortic regurgitation and ventricular dysfunction (ejection fraction 34%) requiring surgical intervention. In pre-operative period, no left ventricular (LV) asynchrony was detected by QRS duration and current echocardiographic techniques, including tissue Doppler imaging. A new echocardiographic technology, the timing of regional volumetric ...
متن کاملNon-invasive Determination of the Optimized Atrioventricular Delay in Patients with Implanted Biventricular Pacing Devices
BACKGROUND Biventricular (BiV) is extensively used in the treatment of congestive heart failure but so far no recommendations for optimized programming of atrioventricular-delay (AVD) settings have been proposed. Can AVD optimization be performed using a simple formula based on non-invasive doppler-echocardiography? METHODS 25 patients (ejection fraction 30+/-8%) received BiV ICDs. Doppler-ec...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 102 9 شماره
صفحات -
تاریخ انتشار 2000