Peritoneal equilibration test with conventional 'low pH/high glucose degradation product' or with biocompatible 'normal pH/low glucose degradation product' dialysates: does it matter?

نویسندگان

  • Lionel Van Overmeire
  • Eric Goffin
  • Jean-Marie Krzesinski
  • Annie Saint-Remy
  • Philippe Bovy
  • Georges Cornet
  • Christophe Bovy
چکیده

BACKGROUND The evaluation of the peritoneal transport characteristics is mandatory in peritoneal dialysis (PD) patients. This is usually performed in routine clinical practice with a peritoneal equilibration test (PET) using conventional dialysates, with low pH and high glucose degradation product (GDP) concentrations. An increasing proportion of patients are now treated with biocompatible dialysates, i.e. with physiological pH and lower GDP concentrations. This questions the appropriateness to perform a PET with conventional solutions in those patients. The aim of our study is to compare the results of the PET using biocompatible and conventional dialysates, respectively. METHODS Nineteen stable PD patients (13 males, 6 females; mean age: 67.95±2.36 years, mean body surface area: 1.83±0.04 m2, dialysis vintage: 2.95±0.19 years) were included, among which 10 were usually treated with biocompatible and 9 with conventional solutions. Two PETs were performed, within a 2-week interval, in each patient. PET sequence (conventional solution first or biocompatible solution first) was randomized in order to avoid 'time bias'. Small (urea, creatinine and glucose), middle (beta-2-microglobulin) and large molecules' (albumin and alpha-2-macroglobulin) dialysate/plasma (D/P) concentration ratios and clearances were measured during each PET. Ultrafiltration (UF) and sodium filtration were also recorded. Results of both tests were compared by the Wilcoxon paired test. RESULTS No statistical difference was found between both dialysates for small molecule transport rates or for sodium filtration and UF. However, a few patients were not similarly classified for small-solute transport characteristics within the PET categories. Beta-2-microglobulin and albumin D/P ratios at different time points of the PET were significantly higher with the biocompatible, when compared with the conventional, solutions: 0.10±0.03 versus 0.08±0.02 (P<0.01) and 0.008±0.003 versus 0.007±0.003 (P=0.01), respectively. A similar difference was also observed for beta-2-microglobulin that was higher with biocompatible dialysates (1.04±0.32 versus 0.93±0.32 mL/min, respectively). CONCLUSION Peritoneal transport of water and small solutes is independent of the type of dialysate which is used. This is not the case for the transport of beta-2-microglobulin and albumin that is higher under biocompatible dialysates. Vascular tonus modification could potentially explain such differences. The PET should therefore always be carried out with the same dialysate to make longitudinal comparisons possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved acidosis correction and recovery of mesothelial cell mass with neutral-pH bicarbonate dialysis solution among children undergoing automated peritoneal dialysis.

Acid-base balance and peritoneal membrane longevity are of utmost relevance for pediatric patients undergoing peritoneal dialysis (PD). PD fluids with neutral pH and reduced glucose degradation product contents are considered more biocompatible, because they preserve peritoneal cell functions in vitro. To investigate the clinical effects of a novel PD fluid buffered with 34 mM pure bicarbonate ...

متن کامل

The effect of low glucose degradation product, neutral pH versus standard peritoneal dialysis solutions on peritoneal membrane function: the balANZ trial

BACKGROUND The balANZ trial recently reported that neutral pH, low glucose degradation product (biocompatible) peritoneal dialysis (PD) solutions significantly delayed anuria and reduced peritonitis rates compared with conventional solutions. This article reports a secondary outcome analysis of the balANZ trial with respect to peritoneal membrane function. METHODS Adult, incident PD patients ...

متن کامل

Effect of the dialysis fluid buffer on peritoneal membrane function in children.

BACKGROUND AND OBJECTIVES Double-chamber peritoneal dialysis fluids exert less toxicity by their neutral pH and reduced glucose degradation product content. The role of the buffer compound (lactate and bicarbonate) has not been defined in humans. DESIGN, SETTING, PARTICIPANTS, & MEASUREMENTS A multicenter randomized controlled trial in 37 children on automated peritoneal dialysis was performe...

متن کامل

New pH-neutral peritoneal dialysis solution, low in glucose degradation products, in a double-chamber bag.

Fresenius Medical Care-North America has developed a neutral-pH version of its Delflex peritoneal dialysis (PD) solution with low glucose degradation products (GDPs): Delflex Neutral pH. The Delflex Neutral pH system stores the PD solution in a dual-chamber bag. The product is admixed by the patient before use. The new design facilitates GDP reduction in two ways. First, GDPs are reduced becaus...

متن کامل

Re: effects of low-glucose degradation product solution on peritoneal membrane characteristics in peritoneal dialysis patients: a 3-year follow-up study.

Dear Editor, In the past issue of the Iranian Journal Kidney Disease, Park and colleagues compared the standard peritoneal dialysis (PD) solution to the low glucose degradation products (GDP) solution in a 3-year follow-up.1 Peritoneal dialysis (PD) is an effective and established form of renal replacement therapy in end -stage renal disease over the past 30 years, which is used by approximatel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 28 7  شماره 

صفحات  -

تاریخ انتشار 2013