The Magnetic Levator Prosthesis for Temporary Management of Severe Blepharoptosis: Initial Safety and Efficacy

نویسندگان

  • Kevin E. Houston
  • Matteo Tomasi
  • Christina Amaral
  • Nicole Finch
  • Michael K. Yoon
  • Hang Lee
  • Eleftherios I. Paschalis
چکیده

Purpose We further optimized and evaluated the safety of the magnetic levator prosthesis (MLP) for temporary management of severe blepharoptosis, and compared efficacy and comfort against the ptosis crutch. Methods The interpalpebral fissure (IPF) of participants (n = 12) with ptosis was measured during attempted eyelid opening, volitional closing, and spontaneous closing with no device, ptosis crutch, or the MLP. A 10-point scale documented comfort. Additionally, a 20 minute and then 1 week trial of the MLP was offered. Safety measures were skin erythema rating, change in visual acuity, and change in corneal staining. Results The MLP and crutch opened the eye (IPF 11.2 and 9.3 mm), but the MLP allowed better volitional closure (IPF 1.0 vs. 4.9 mm, P = 0.009), but was no better in allowing spontaneous blink (IPF 7.5 vs. 7.7 mm, P = 0.722). Both devices were equally comfortable (both median 8/10 comfort, P = 0.46). With extended use, opening with the MLP showed IPF 9.24 mm at 20 minutes and 9.46 mm at 1 week, and volitional closure was IPF 0.95 and 0.52 mm, respectively. Closure on spontaneous blink improved with extended wear to IPF 5.14 and 5.18 mm, respectively (P = 0.002). Two participants exhibited moderate skin erythema and one had increased corneal staining without change in acuity. Conclusions The MLP is safe and feasible for temporary correction of severe ptosis. Translational Relevance First group data in patients showing successful reanimation of the eyelid with magnetic force.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Polybutylate-Coated Braided Polyester (Ethibond) Sutures for Levator-Advancement Blepharoptosis Repair

Purpose. To evaluate the efficacy and safety of polybutylate-coated braided polyester (Ethibond* 5-0) suture for levator aponeurosis suturing to the anterior tarsal surface in involutional blepharoptosis repair surgery. Methods. Ten consecutive patients (16 eyes) with acquired blepharoptosis which resulted from levator aponeurosis dehiscence with good levator function had gone through surgery a...

متن کامل

A Prototype External Magnetic Eyelid Device for Blepharoptosis.

PURPOSE To test a prototype magnet system (magnetic levator prosthesis) for the ability to comfortably and non-invasively provide eye opening with maintenance of the blink in people with paralytic ptosis and determine preliminary efficacy for short-term clinical application. METHODS The prototype device consisted of a magnet on a spectacle frame and a micro-magnet array mounted externally on ...

متن کامل

A case of surgical repair in strabismus fixus with ptosis.

Strabismus fixus is very rare and the convergent form is rarely accompanied by blepharoptosis. We successfully treated one patient with high myopia whose convergent strabismus fixus, accompanied by blepharoptosis, became severe after cataract surgery. We report the case with a discussion of its pathology. We performed levator advancement operation, bilateral lateral rectus 11 mm resection, and ...

متن کامل

Evaluation of the efficacy and safety of botulinum toxin type A to induce temporary ptosis in dogs.

PURPOSE To verify the safety and efficacy of botulinum toxin type A (BoNT/A) to promote protective ptosis in dogs. METHODS In this prospective interventional study, a total of 10 dogs underwent transcutaneous anterior chemodenervation of levator palpebral superioris with 15 U of BoNT/A. The systemic changes, ocular mobility, visual function, intraocular pressure (IOP), tear production, and th...

متن کامل

Analysis of visual outcomes and complications following levator resection for unilateral congenital blepharoptosis without strabismus.

BACKGROUND It is challenging to manage congenital blepharoptosis, especially unilateral, because symmetry is difficult to achieve under general anesthesia and age at which the ptosis should be corrected is still controversial. The aim of our study is to analyze visual and surgical outcomes after levator resection for unilateral congenital blepharoptosis. METHODS Charts of patients with unilat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2018