Preventing PCR amplification carryover contamination in a clinical laboratory.
نویسنده
چکیده
During the past two decades PCR and several other DNA/RNA amplification techniques have become important diagnostic tools in clinical laboratories. Amplification products contamination has been the main impediment to using these techniques routinely in diagnostic laboratories. Over the years, several creative pre- and post-amplification methods have been developed that prevent amplicon carryover contamination. These procedures, coupled with automated systems that employ real-time amplification and simultaneous detection in a closed system, have substantially reduced the possibility of false positive results due to amplification products carryover contamination.
منابع مشابه
Simple enzymatic means to neutralize DNA contamination in nucleic acid amplification.
Reverse transcription PCR (RT-PCR) is prone to false positives when contaminating DNA molecules are present at the start of a reaction. Contaminants that derive from earlier work using a given primer pair (carryover PCR products) are of particular concern when those primers are used routinely, as in clinical diagnostics or environmental monitoring. In addition, contamination by genomic DNA can ...
متن کاملRegeneration of commercial nucleic acid extraction columns without the risk of carryover contamination.
Nucleic acid extraction is a basic requirement in a molecular biology laboratory. In terms of purity and yield, commercial nucleic acid extraction columns are superior; however they are expensive. We report here an efficient strategy to regenerate diverse commercial columns for several rounds without altering the binding capacity of the columns or changing the properties of the nucleic acids pu...
متن کاملDevelopment and evaluation of a real-time quantitative PCR for the detection of human cytomegalovirus.
A novel real-time quantitative PCR (QPCR) assay is described for monitoring CMV DNA load in clinical specimens using the LightCycler. The assay is rapid (< 40 min), easy to carry out, robust, reliable and is capable of detecting from 10 to over 2 x 10(5) CMV DNA copies with a wide linear range. Amplification and detection occur simultaneously, avoiding the need for post-PCR analysis and thereby...
متن کاملContaminations occurring in fungal PCR assays.
Successful in vitro amplification of fungal DNA in clinical specimens has been reported recently. In a collaboration among five European centers, the frequency and risk of contamination due to airborne spore inoculation or carryover contamination in fungal PCR were analyzed. The identities of all contaminants were specified by cycle sequencing and GenBank analysis. Twelve of 150 PCR assays that...
متن کاملMinimizing DNA contamination by using UNG-coupled quantitative real-time PCR on degraded DNA samples: application to ancient DNA studies.
PCR analyses of ancient and degraded DNA suffer from their extreme sensitivity to contamination by modern DNA originating, in particular, from carryover contamination with previously amplified or cloned material. Any strategy for limiting carryover contamination would also have to be compatible with the particular requirements of ancient DNA analyses. These include the need (i) to amplify short...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of clinical and laboratory science
دوره 34 4 شماره
صفحات -
تاریخ انتشار 2004