Determination of Vitamin E in Olive Oil Using the Agilent 1260 Infi nity Analytical SFC System Rapid, high-resolution separation of all isomers of tocopherol and tocotrienol
نویسنده
چکیده
This Application Note demonstrates the separation of eight tocopherol and tocotrienol compounds by supercritical fl uid chromatography (SFC) using the Agilent 1260 Infi nity Analytical SFC system. Calibration curves were generated for all compounds, and a real-life virgin olive oil sample was analyzed. The limits of detection and quantifi cation (LOD and LOQ) were determined as well as relative standard deviations (RSDs) of retention times and areas. a-T oco phe rol a-T oco trie nol b-T oco phe rol g-T oco phe rol b-T oco trie nol g-T oco trie nol d-T oco phe rol d-T oco trie nol
منابع مشابه
Determination of Enantiomeric Excess of Metolachlor from Chiral Synthesis using the Agilent 1260 Infi nity Analytical SFC System
This Application Note describes the development of a method for the separation of four stereoisomers, which were derived from a compound with two steric centers. The method was developed using an Agilent 1260 Infi nity Analytical Supercritical Fluid Chromatography (SFC) solution with Agilent ChemStation Method Scouting Wizard software. The developed method was used to compare the ratio of stere...
متن کاملEnantiomer separation of non - steroidal anti - infl ammatory drugs Using Daicel immobilized polysaccharide - derived chiral columns and the Agilent 1260 Infi nity Analytical SFC System Application
The enantiomer separation by supercritical fl uid chromatography (SFC) of six profen drugs was investigated on the new generation of chiral columns from Daicel Corporation, that are packed with the immobilized polysaccharide-derived chiral stationary phases CHIRALPAK IA, CHIRALPAK IB, CHIRALPAK IC, and CHIRALPAK ID. Methanol, ethanol, 2-propanol and acetonitrile were used in combination with tr...
متن کاملQuality analysis of virgin olive oils – Part 2 Thermal treatment analysis – determination of polymerized triglycerides with SEC/GPC using the Agilent 1260 Infi nity LC System with Refractive Index Detection
This Application Note shows the analysis of polymerized triacylglycerides in olive oil using the Agilent 1260 Infi nity LC with size exclusion chromatography/gel permeation chromatography (SEC/GPC) with refractive index detection (RID). The analysis of six virgin olive oils revealed only minor amounts of polymerized triacylglycerides (PTAGs) indicating no refi ning or other thermal treatment pr...
متن کاملMethod Development to Separate Enantiomers by Supercritical Fluid Chromatography
This Application Note demonstrates the use of the Agilent 1260 Infi nity Analytical SFC Solution for method screening for the separation of enantiomers. To enhance the 1260 Infi nity SFC Solution for method development and screening, a second thermostatted column compartment and two column selection valves were added for column selection, together with a 12-position/13-port valve for solvent se...
متن کاملTransfer of USP Cholecalciferol Normal-phase HPLC Method to SFC Using the Agilent 1260 Infi nity Hybrid SFC/UHPLC System
The Agilent 1260 Infi nity Hybrid SFC/UHPLC System offers a fast, reliable, green, robust, and cost-effective solution by coupling the advantages of HPLC and the benefi ts of supercritical fl uid chromatography (SFC). This Application Note describes the conversion of the United States Pharmacopeia (USP) normal-phase HPLC method for cholecalciferol assay to an SFC method using serially coupled c...