CT evaluation of apical canal transportation associated with stainless steel hand files, oscillatory technique and pro taper rotary system.

نویسندگان

  • Mateus Silveira Martins Hartmann
  • Vânia Regina Camargo Fontanella
  • José Roberto Vanni
  • Volmir João Fornari
  • Fernando Branco Barletta
چکیده

This study used computed tomography (CT) to compare apical canal transportation in mesiobuccal canals of maxillary molars prepared with different techniques. Sixty teeth were assigned to 3 groups (n=20), according to the technique used for root canal instrumentation: hand instrumentation with K-Flexofiles, K-Flexofiles activated by an oscillatory system and ProTaper NiTi rotary system. Pre and post-instrumentation CT images were obtained 3 mm short of the apical foramen and were superimposed to compare canal transportation. Data were analyzed statistically by ANOVA and Tukey's test using the SPSS software (α=0.05). In the buccal direction, the manual technique produced significantly less canal transportation than the oscillatory technique (p<0.05) and both were similar to the rotary technique (p>0.05). In the distal and distopalatal directions, the oscillatory technique produced more canal transportation (p<0.05). In the mesiopalatal direction, the oscillatory technique produced more canal transportation than the manual technique (p<0.05), and both were similar to the rotary technique (p>0.05). In conclusion, all techniques produced canal transportation, and the oscillatory technique produced the greatest removal of root dentin toward the innerside of the root curvature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of preparation techniques on root canal shaping assessed by micro-computed tomography

BACKGROUND Root canal shaping without any procedural error is of the utmost preference. Therefore, the purpose of this study was to use micro-computed tomography to evaluate and compare the root canal shaping efficacy of ProTaper rotary files and standard stainless steel K-files. MATERIAL AND METHODS Sixty extracted upper second premolars were selected and were divided into 2 groups of 30. Be...

متن کامل

An in-vitro Evaluation of canal transportation and centering ability of two rotary Nickel Titanium systems (Twisted Files and Hyflex files) with conventional stainless Steel hand K-flexofiles by using Spiral Computed Tomography.

BACKGROUND The purpose of this in-vitro study was to compare canal transportation and centering ability of Twisted and Hyflex Rotary Files with stainless steel hand k-flexofiles by using Spiral Computed Tomography. MATERIALS & METHODS A total of 90 freshly extracted human mandibular single rooted Premolar teeth were selected. The crowns were flattened with steel disks and a final dimension of...

متن کامل

Re: A micro-computed tomographic evaluation of apical root canal preparation using three instrumentation techniques.

AIM To investigate the morphological changes in the apical third of the root canal after preparation with three techniques. METHODOLOGY Forty molar teeth were scanned using micro-computed tomography before and after instrumentation with: Group 1 - stainless steel K-files using the balanced force technique; Group 2 - stainless steel K-files (balanced force) and then refining the apical prepara...

متن کامل

Chemomechanical preparation by hand instrumentation and by Mtwo engine-driven rotary files, an ex vivo study

OBJECTIVE To compare the disinfecting efficacy of the sodium hypochlorite irrigation by root canal preparation with stainless steel hand files, taper 0.02 and nickel-titanium Mtwo files with taper 0.04-0.06. STUDY DESIGN 40 extracted human teeth were sterilized, and then inoculated with Enterococcus faecalis (ATCC 29212). After 6 day incubation time the root canals were prepared by hand with ...

متن کامل

A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro)

A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro) Dr. MR. Sharifian* - Dr. MH. Nekoofar* - Dr. P. Motahari** - Dr. A. Tavakoli*** *-Assistant Professor of Endodontics Dept. – Faculty of Dentistry – Tehran University of Medical Sciences. **- Assistant Professor of Oral and Maxillofacial Pathology Dept. – Facul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian dental journal

دوره 22 4  شماره 

صفحات  -

تاریخ انتشار 2011