Validation of functional calibration and strap-down joint drift correction for computing 3D joint angles of knee, hip, and trunk in alpine skiing
نویسندگان
چکیده
To obtain valid 3D joint angles with inertial sensors careful sensor-to-segment calibration (i.e. functional or anatomical calibration) is required and measured angular velocity at each sensor needs to be integrated to obtain segment and joint orientation (i.e. joint angles). Existing functional and anatomical calibration procedures were optimized for gait analysis and calibration movements were impractical to perform in outdoor settings. Thus, the aims of this study were 1) to propose and validate a set of calibration movements that were optimized for alpine skiing and could be performed outdoors and 2) to validate the 3D joint angles of the knee, hip, and trunk during alpine skiing. The proposed functional calibration movements consisted of squats, trunk rotations, hip ad/abductions, and upright standing. The joint drift correction previously proposed for alpine ski racing was improved by adding a second step to reduce separately azimuth drift. The system was validated indoors on a skiing carpet at the maximum belt speed of 21 km/h and for measurement durations of 120 seconds. Calibration repeatability was on average <2.7° (i.e. 3D joint angles changed on average <2.7° for two repeated sets of calibration movements) and all movements could be executed wearing ski-boots. Joint angle precision was <4.9° for all angles and accuracy ranged from -10.7° to 4.2° where the presence of an athlete-specific bias was observed especially for the flexion angle. The improved joint drift correction reduced azimuth drift from over 25° to less than 5°. In conclusion, the system was valid for measuring 3D joint angles during alpine skiing and could be used outdoors. Errors were similar to the values reported in other studies for gait. The system may be well suited for within-athlete analysis but care should be taken for between-athlete analysis because of a possible athlete-specific joint angle bias.
منابع مشابه
Kinematics of Hip, Knee and Ankle During Cross- Slope Walking
Purpose: Little information is available on joint kinematic adaptations during walking on cross-slope surfaces (i.e. a surface incline perpendicular to the direction of locomotion). This study aimed to evaluate the effects of cross-slope surfaces on three-dimensional (3D) kinematics of hip, knee, and ankle joints during stance phase of walking. Methods: This is a quasi-experimental study...
متن کاملEffect of Soccer Specific Functional Fatigue On hip and knee Joints Kinematics In professional players during Landing
The purpose of this study was to investigate the effect of soccer specific functional fatigue on hip and knee joints angles during landing in professional players.15 soccer players with at least 2 years experience in Kerman soccer clubs were selected randomly. To evaluate the lower extremity kinematics following jumping and soccer specific- heading, three cameras (with50Hz) were used. To cau...
متن کاملThe Effect of Hip Bracing on Gait in Patients with Medial Knee Osteoarthritis
Objective. Impaired hip motion has been associated with heightened medial knee joint loading in patients with knee osteoarthritis (OA). A hip external rotation strap designed to pull the femur into external rotation and abduction may serve as one protective mechanism. The primary aim of our study is to determine if the strap decreases medial knee joint loading during level walking in people wit...
متن کاملAnterior Cruciate Ligament Forces in Alpine Skiing.
The purpose of this study was to estimate cruciate ligament forces in Alpine skiing during a movement that has been associated with anterior cruciate ligament (ACL) tears. Resultant knee joint forces and moments were obtained from two skiers during a World Cup Downhill race using an inverse dynamics approach and a 2-D bilaterally symmetric system model. It was found that ACL forces were typical...
متن کاملAnalysis of the Geometry of the Distal Femur and Proximal Tibia in the Osteoarthritic Knee: A 3D Reconstruction CT Scan Based Study of 449 Cases
Background: The aim of this study is to evaluate the geometry of the distal femur and the proximal tibia in the osteoarthritic knee using 3D reconstructive CT scan imaging. Methods: 449 patients with knee osteoarthritis were treated surgically in our center with patient-specific technology total knee arthroplasty. Preoperatively, all the patients underwent a CT scan according to a standard ...
متن کامل