Experimental evaluation of optimized ablation patterns for laser refractive surgery.

نویسندگان

  • Carlos Dorronsoro
  • Laura Remon
  • Jesús Merayo-Lloves
  • Susana Marcos
چکیده

A new experimental model based on plastic (Filofocon A) artificial eyes was used to study the ablation profiles and the outcomes of three state-of-the-art refractive surgery excimer lasers provided with narrow-beam flying spot and optimized algorithms (Ladarvision 4000, Alcon; Technolas 217 Z100, Bausch and Lomb; Allegretto wave Eye-Q, Wavelight). The 3-D ablation patterns produced by myopic laser corrections (-9, -6 and -3 D) on flat and spherical surfaces of Filofocon A were measured using high resolution optical profilometry. We found significant differences across lasers in the shape and depth of the ablation patterns. A comparison of the ablation patterns on flat and on spherical surfaces provided a measurement of the laser efficiency losses from the center to the periphery at each point of the spherical plastic corneas. This effect also varied across lasers, depending on their fluence (120-400 mJ/cm(2)). Estimates of the post-operative corneal shapes were obtained from the measurement on Filofocon A and plastic-corneal tissue correction factors. The predicted post-operative corneal ablation shape, ablated volume, asphericity and spherical aberration varied across lasers, as well as the relative contribution of ablation pattern designs and efficiency losses to the increased asphericity. Although the results show that the algorithms have been optimized to reduce the induction of spherical aberration, they would still benefit from the application of correction factors for efficiency effects derived from a systematic approach using experimental plastic models. These models have proved useful (1) to assess the outcomes of different lasers or ablation algorithms, (2) for precise calibration and testing of the lasers, and (3) to calculate experimental correction factors for efficiency effects.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Outcomes of an Optimized Prolate Ablation Procedure for Correcting Residual Refractive Errors Following Laser Surgery

PURPOSE The purpose of this study was to investigate the clinical efficacy of an optimized prolate ablation procedure for correcting residual refractive errors following laser surgery. METHODS We analyzed 24 eyes of 15 patients who underwent an optimized prolate ablation procedure for the correction of residual refractive errors following laser in situ keratomileusis, laser-assisted subepithe...

متن کامل

Effect of air-flow on the evaluation of refractive surgery ablation patterns.

An Allegretto Eye-Q laser platform (Wavelight GmbH, Erlangen, Germany) was used to study the effect of air-flow speed on the ablation of artificial polymer corneas used for testing refractive surgery patterns. Flat samples of two materials (PMMA and Filofocon A) were ablated at four different air flow conditions. The shape and profile of the ablated surfaces were measured with a precise non-con...

متن کامل

Suitability of Filofocon A and PMMA for experimental models in excimer laser ablation refractive surgery.

Experimental corneal models in plastic (in PMMA, and more recently in Filofocon A, a contact lens material) have been proposed recently to overcome some of the limitations of the theoretical approaches aiming at improving the predictability of corneal reshaping by laser ablation. These models have also been proposed for accurate assessment of corneal laser ablation patterns. In this study Filof...

متن کامل

Wavefront-guided laser in situ keratomileusis: early results in three eyes.

PURPOSE Wavefront optical aberrations induced by refractive corneal surgery correction of myopia are probably the reason for deterioration of visual performance in some eyes after surgery. Customized photoablation of the cornea to correct both the sphero-cylindrical refractive error as well as individual optical aberrations may improve postoperative visual acuity and visual performance. METHO...

متن کامل

Optimized prolate ablations with the NIDEK CXII excimer laser.

PURPOSE To describe a novel excimer laser ablation algorithm, termed optimized prolate ablation (OPA), that uses both topography and ocular aberrometry and maintains or improves the natural corneal shape postoperatively. METHODS A descriptive article outlining the theory behind this OPA algorithm. RESULTS The theoretical changes to the ablation algorithm described in this article will produ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 17 17  شماره 

صفحات  -