Fixation of Intertrochanteric Fractures: Dynamic Hip Screw versus Locking Compression Plate
نویسندگان
چکیده
BACKGROUND According to the existing literature, the Dynamic Hip Screw (DHS) is the preferred standard for the treatment of intertrochanteric fractures. However, some surgeons use other devices such as the Locking Compression Plate (LCP). OBJECTIVES In this study, we compared the outcome of using DHS or LCP in intertrochanteric fractures. MATERIALS AND METHODS This cross-sectional study was carried out on 104 patients who were referred to Pursina Hospital in Rasht, Iran with intertrochanteric fractures of the femur treated with either the DHS or LCP devices. Demographic features, existence or nonexistence of stability and operating time were obtained from questionnaires. During a 6-month follow-up after surgery, patients were interviewed to record variables such as Harris Hip Scores and complications. The patients were also interviewed on their final visit (between 9 and 31 postoperative months). The collected data was analyzed using SPSS. RESULTS We discovered that the number of incidences of limb shortening and device failure was higher for patients treated with the LCP device (P = 0.048 and P = 0.014). Patients treated with the DHS device had higher Harris Hip scores for both the 6-month postoperative and the final evaluation visits (P = 0.01 and P = 0.018). CONCLUSIONS Despite the complications of fixation with the DHS device, it remains the most successful for treatment of intertrochanteric fractures.
منابع مشابه
Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques
Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...
متن کاملA Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate
Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...
متن کاملType II Intertrochanteric Fractures: Proximal Femoral Nailing (PFN) Versus Dynamic Hip Screw(DHS)
Background: Intertrochanteric fracture is one of the most common fractures of the hip especially in the elderly with osteoporotic bones, usually due to low-energy trauma like simple falls. Dynamic Hip Screw (DHS) is still considered the gold standard for treating intertrochanteric fractures by many. Not many studies compare the DHS with Proximal femoral nail (PFN), in Type II intertrochanteri...
متن کاملبررسی کاربرد Short barrel DHS در درمان شکستگی انترتروکانتریک
Cut out or extrusion of the lag screw from the superior aspect of head and neck of the femur is one of the most common and devastating complications of the surgery of the intertrochanteric fractures with DHS. The exact cause of this complications is unknown, but it seems to be related to osteopenia, inappropriate position of lag screw inside head of the femur and inability of DHS to slide insid...
متن کاملMinimal Invasive Dynamic Hip Screw for Intertrochanteric Fractures
DOI: 10.21276/sjams.2017.5.9.32 Abstract: Intertrochanteric fracture of femur is one of the most common fracture of the hip especially in elderly with osteoporotic bones, usually due to low energy trauma like simple falls. With rise in Osteoporosis and geriatric population the risk of getting intertrochanteric fracture is on rise. Rigid fixation with early mobilization of patients is the standa...