Quality assurance evaluation of delivery of respiratory‐gated treatments
نویسندگان
چکیده
We describe a method for evaluating the quality of respiratory-gated radiation delivery using a commercially available device. During irradiation, gating traces for one field for each treatment were extracted from the system for each of 14 patients. The data were then transferred to a spreadsheet. Software was developed to evaluate the following parameters: duty cycle, amplitude of fiducial motion, fraction of amplitude of motion during gated delivery, and respiratory cycle time. Criteria were established for acceptability of gating traces. In our sample, over 85% of the traces indicated acceptability. An example of results for one patient extracted from analyzed gating traces is as follows: mean duty cycle, 57%, average amplitude of motion, 0.89 cm, average fraction of motion during gated delivery, 0.45; mean respiratory cycle time, 4.5 s. This technique can be used to evaluate delivery of respiratory-gated radiation therapy for quality assurance purposes and to assess various techniques for improving delivery of gated therapy. A hardcopy of the gating traces can be used to document gated treatment delivery for potential billing of the gated delivery process.
منابع مشابه
Performance evaluation of gated volumetric modulated arc therapy
Background: Aim of this study is to evaluate the accuracy of the gated volumetric modulated arc therapy (VMAT/RapidArc) using 2D planar dosimetry, DynaLog files and COMPASS 3D dosimetry system. Materials and Methods: Pre-treatment quality assurance of 10 gated VMAT plans was verified using 2D array and COMPASS 3D dosimetry system. Advantage of COMPASS over 2D planar is that it provides the clin...
متن کاملThe clinical implementation of respiratory-gated intensity-modulated radiotherapy.
The clinical use of respiratory-gated radiotherapy and the application of intensity-modulated radiotherapy (IMRT) are 2 relatively new innovations to the treatment of lung cancer. Respiratory gating can reduce the deleterious effects of intrafraction motion, and IMRT can concurrently increase tumor dose homogeneity and reduce dose to critical structures including the lungs, spinal cord, esophag...
متن کاملDosimetric characteristics of a new linear accelerator under gated operation
Respiratory gated radiotherapy may allow reduction of the treatment margins, thus sparing healthy tissue and/or allowing dose escalation to the tumor. However, current commissioning and quality assurance of linear accelerators do not include evaluation of gated delivery. The purpose of this study is to test gated photon delivery of a Siemens ONCOR Avant-Garde linear accelerator. Dosimetric char...
متن کاملCharacteristics of gated treatment using an optical surface imaging and gating system on an Elekta linac
BACKGROUND Knowing the technical characteristics of gated radiotherapy equipment is crucial for ensuring precise and accurate treatment when using techniques such as Deep-Inspiration Breath-Hold and gating under free breathing. With one of the first installations of the novel surface imaging system Catalyst™ (C-RAD AB, Sweden) in connection with an Elekta Synergy linear accelerator (Elekta AB, ...
متن کاملImplementation of respiratory‐gated VMAT on a Versa HD linear accelerator
The accurate delivery of respiratory-gated volumetric modulated arc therapy (VMAT) treatment plans presents a challenge since the gantry rotation and collimator leaves must be repeatedly stopped and set into motion during each breathing cycle. In this study, we present the commissioning process for an Anzai gating system (AZ-733VI) on an Elekta Versa HD linear accelerator and make recommendatio...