SISCAPA peptide enrichment on magnetic beads using an in-line bead trap device.

نویسندگان

  • N Leigh Anderson
  • Angela Jackson
  • Derek Smith
  • Darryl Hardie
  • Christoph Borchers
  • Terry W Pearson
چکیده

A SISCAPA (stable isotope standards and capture by anti-peptide antibodies) method for specific antibody-based capture of individual tryptic peptides from a digest of whole human plasma was developed using a simplified magnetic bead protocol and a novel rotary magnetic bead trap device. Following off-line equilibrium binding of peptides by antibodies and subsequent capture of the antibodies on magnetic beads, the bead trap permitted washing of the beads and elution of bound peptides inside a 150-microm-inner diameter capillary that forms part of a nanoflow LC-MS/MS system. The bead trap sweeps beads against the direction of liquid flow using a continuous succession of moving high magnetic field-gradient trap regions while mixing the beads with the flowing liquid. This approach prevents loss of low abundance captured peptides and allows automated processing of a series of SISCAPA reactions. Selected tryptic peptides of alpha(1)-antichymotrypsin and lipopolysaccharide-binding protein were enriched relative to a high abundance serum albumin peptide by 1,800 and 18,000-fold, respectively, as measured by multiple reaction monitoring. A large majority of the peptides that are bound nonspecifically in SISCAPA reactions were shown to bind to components other than the antibody (e.g. the magnetic beads), suggesting that substantial improvement in enrichment could be achieved by development of improved inert bead surfaces.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An automated and multiplexed method for high throughput peptide immunoaffinity enrichment and multiple reaction monitoring mass spectrometry-based quantification of protein biomarkers.

There is an urgent need for quantitative assays in verifying and validating the large numbers of protein biomarker candidates produced in modern "-omics" experiments. Stable isotope standards with capture by anti-peptide antibodies (SISCAPA) has shown tremendous potential to meet this need by combining peptide immunoaffinity enrichment with quantitative mass spectrometry. In this study, we desc...

متن کامل

High-Throughput SISCAPA-Based Peptide Quantitation Using an Agilent RapidFire High-Throughput Mass Spectrometry System

A high-throughput SISCAPA workfl ow has been developed that uses RapidFire/MS technology to enable sensitive quantitation of peptides from plasma digests with a sample cycle time of approximately 10 seconds. The optimized system includes capture of target proteotypic peptides using rigorously selected, high affi nity antipeptide monoclonal antibodies and reduction of background peptides using a...

متن کامل

Pulling on super paramagnetic beads with micro cantilevers: single molecule mechanical assay application.

This paper demonstrates that it is possible to trap and release a super paramagnetic micro bead by fixing three super paramagnetic micro beads in a triangular array at the sensitive end of a micro cantilever, and by simply switching on/off an external magnetic field. To provide evidence of this principle we trap a micro bead that is attached to the free end of single DNA molecule and that has b...

متن کامل

Microchip emitter for solid-phase extraction-gradient elution-mass spectrometry.

A microchip electrospray emitter with a magnetic bead trap has been designed for solid-phase extraction-gradient elution-mass spectrometry (SPE-GEMS). The goal of this method is the detection of analytes at low concentrations and it is here demonstrated using reverse phase coated magnetic beads (Mbs) for the preconcentration and detection of the peptides. The sample is passed through the chip, ...

متن کامل

Rapid and continuous magnetic separation in droplet microfluidic devices.

We present a droplet microfluidic method to extract molecules of interest from a droplet in a rapid and continuous fashion. We accomplish this by first marginalizing functionalized super-paramagnetic beads within the droplet using a magnetic field, and then splitting the droplet into one droplet containing the majority of magnetic beads and one droplet containing the minority fraction. We quant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Molecular & cellular proteomics : MCP

دوره 8 5  شماره 

صفحات  -

تاریخ انتشار 2009