πSPIM: high NA high resolution isotropic light-sheet imaging in cell culture dishes

نویسندگان

  • Patrick Theer
  • Denitsa Dragneva
  • Michael Knop
چکیده

Light-sheet fluorescence microscopy (LSFM), also termed single plane illumination microscopy (SPIM), enables live cell fluorescence imaging with optical sectioning capabilities superior to confocal microscopy and without any out-of-focus exposure of the specimen. However, the need of two objective lenses, one for light-sheet illumination and one for imaging, imposes geometrical constraints that require LSFM setups to be adapted to the specific needs of different types of specimen in order to obtain optimal imaging conditions. Here we demonstrate the use of an oblique light-sheet configuration adapted to provide the highest possible Gaussian beam enabled resolution in LSFM. The oblique light-sheet configuration furthermore enables LSFM imaging at the surface of a cover slip, without the need of specific sample mounting. In addition, the system is compatible with simultaneous high NA wide-field epi-fluorescence imaging of the specimen contained in a glass-bottom cell culture dish. This prevents cumbersome sample mounting and enables rapid screening of large areas of the specimen followed by high-resolution LSFM imaging of selected cells. We demonstrate the application of this microscope for in toto imaging of endocytosis in yeast, showing for the first time imaging of all endocytic events of a given cell over a period of >5 minutes with sub-second resolution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SPED Light Sheet Microscopy: Fast Mapping of Biological System Structure and Function

The goal of understanding living nervous systems has driven interest in high-speed and large field-of-view volumetric imaging at cellular resolution. Light sheet microscopy approaches have emerged for cellular-resolution functional brain imaging in small organisms such as larval zebrafish, but remain fundamentally limited in speed. Here, we have developed SPED light sheet microscopy, which comb...

متن کامل

Reflective imaging improves resolution, speed, andcollection efficiency in light sheet microscopy

Light-sheet fluorescence microscopy (LSFM) enables high-speed, high-resolution, gentle imaging of live biological specimens over extended periods. Here we describe a technique that improves the spatiotemporal resolution and collection efficiency of LSFM without modifying the underlying microscope. By imaging samples on reflective coverslips, we enable simultaneous collection of multiple views, ...

متن کامل

A noninvasive transfer system for polarized renal tubule epithelial cell sheets using temperature-responsive culture dishes.

We used temperature-responsive culture dishes onto which the temperature-responsive polymer, poly(Nisopropylacrylamide), was covalently grafted for tissue engineering. Confluent cells harvested as intact sheets from these surfaces by simple temperature reduction can be transferred to various surfaces including additional culture dishes, other cell sheets, and tissues. In order to examine the ma...

متن کامل

Light Sheet Fluorescence Microscopy Combined with Optical Clearing Methods as a Novel Imaging Tool in Biomedical Research

In the past decade, imaging has advanced to become a crucial tool in fundamental and biomedical research and it has become increasingly important to be able to image whole organs with single cell resolution. Light sheet fluorescence microscopy, also called selective plane illumination microscopy or ultramicroscopy, provides a high resolution in transparent and intact whole organs. By the applic...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2016