Minimization of Imaging Artifacts from Profile Ordering of Randomly Selected ky-kz Lines for Prospective Compressed- Sensing Acqusition in 3D Segmented SSFP and GRE Imaging

نویسندگان

  • T. A. BASHA
  • M. AKCAKAYA
  • M. H. MOGHARI
  • K. V. KISSINGER
  • B. GODDU
  • L. GOEPFERT
  • W. J. MANNING
  • R. NEZAFAT
چکیده

Fig. 2: In-vivo results for RCA images: a) Reference image, b) Image from simulated prospective undersampling (R=1, i.e. data is fully sampled) with random profile ordering, c) Reconstructed image from true prospective undersampling (R=2) with proposed profile ordering. Minimization of Imaging Artifacts from Profile Ordering of Randomly Selected ky-kz Lines for Prospective CompressedSensing Acqusition in 3D Segmented SSFP and GRE Imaging

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Compressed Sensing for Motion Artifact Reduction

Introduction: Navigators can effectively track rigid-body motion of limited amplitude, such as respiratory motion [1,2,3]. In a Cartesian scan, data is corrected by applying to each k-space line the phase modulation corresponding to the amount of detected motion. However, lines associated with significant motion (e.g., swallowing in larynx imaging) are uncorrectable and therefore need to be dis...

متن کامل

Accelerating Magnetic Resonance Imaging through Compressed Sensing Theory in the Direction space-k

Magnetic Resonance Imaging (MRI) is a noninvasive imaging method widely used in medical diagnosis. Data in MRI are obtained line-by-line within the K-space, where there are usually a great number of such lines. For this reason, magnetic resonance imaging is slow. MRI can be accelerated through several methods such as parallel imaging and compressed sensing, where a fraction of the K-space lines...

متن کامل

Improved Time-Resolved, 3D Phase Contrast Imaging through Variable Poisson Sampling and Partial Respiratory Triggering

INTRODUCTION Time-resolved 3-dimensional phase-contrast MR imaging (4D-PC MRI) has been shown to be an important tool in a wide variety of research applications, such as wall shear stress measurements [1], aortic pulse wave velocity measurements [2], and the investigation of flow patterns in the heart [3]. The adoption of this technique in routine clinical imaging is primarily hampered by two i...

متن کامل

Myocardial first pass perfusion: steady-state free precession versus spoiled gradient echo and segmented echo planar imaging.

The imaging sequences used in first pass (FP) perfusion to date have important limitations in contrast-to-noise ratio (CNR), temporal and spatial resolution, and myocardial coverage. As a result, controversy exists about optimal imaging strategies for FP myocardial perfusion. Since imaging performance varies from subject to subject, it is difficult to form conclusions without direct comparison ...

متن کامل

Evaluation of Sensory Pathways in Spinal Cord by Comparison of fMRI Methodologies

Introduction: Today, clinicians and neuroscientists need to have a comprehensive survey of neurological pathologies and injuries. For the First-time, SEEP contrast and Spin-Echo pulse sequences was used for functional imaging of the Lumbar spinal cord. This method used by several research groups for Spinal cord mapping, but other researchers tried to improve BOLD fMRI to Spina...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010