In order to detect grid harmonic and reactive current precisely and real time, this paper arrived at a method of harmonic and reactive current real-time detection applied to active power filter based on the three-phase circuit instantaneous reactive power theory. With Matlab simulation software, researches on simulation of harmonic detection means are carried out, and an analysis of the simulation result is presented. The result indicates: the harmonic detection means based on instantaneous reactive power theory can detect harmonic and reactive component in three-phase current precisely and realtime and provide reliable harmonic and reactive current for harmonic restraint and reactive power compensation. Therefore, this method can provide reliable indicator parameters for researches and development of APF and SVC. Keywords-Instantaneous reactive power theory, harmonic current detection, simulation
منابع مشابه
ارائۀ روش کنترلی جدید برای فیلترهای اکتیو موازی در سیستمهای سهفاز چهارسیمه بهمنظور جبرانسازی هارمونیکها، نامتعادلی و توان راکتیو
In this paper, a novel control strategy for a Shunt Active Power Filter (shunt-APF) is proposed. In the proposed control strategy which is based on a new application of the instantaneous reactive power theory, the current injected by the shunt-APF is capable of compensation for the reactive component, the harmonic components and also unbalance of the load current. In this strategy, the shunt-AP...
متن کاملA New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)
This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...
متن کاملActive Filter Control Method Based on Direct Power Control for Compensating Reactive Powers due to Unbalanced Voltages and Nonlinear Loads
Active filters have proven to be more effective than passive techniques to improve power quality and to solve harmonic and power factor problems due to nonlinear loads. This paper proposes a control scheme based on the instantaneous active and reactive power. The inverter of this active filter is a three-phase, two-level converter. Space vector technique is used as modulators and pattern genera...
متن کاملA New Control Method for Single-Phase Grid-Connected Inverter Using Instantaneous Power Theory
Because of installation for local consumers and since it is free of all contaminations, connecting photovoltaic cells to the grid via single-phase inverter is significantly on the rise. In this paper, a new simple current control is proposed for a single-phase grid-connected voltage source inverter. Using the PQ theory and modelling a single-phase system as an unbalanced three-phase system, a m...
متن کاملA Novel Controller Based on Single-Phase Instantaneous p-q Power Theory for a Cascaded PWM Transformer-less STATCOM for Voltage Regulation
In this paper, dynamic performance of a transformerless cascaded PWM static synchronous shunt compensator (STATCOM) based on a novel control scheme is investigated for bus voltage regulation in a 6.6kV distribution system. The transformerless STATCOM consists of a thirteen-level cascaded H-bridge inverter, in which each voltage source H-bridge inverter should be equipped with a floating and iso...
متن کامل