National standard for measurement of resting and ambulatory blood pressures with automated sphygmomanometers.
نویسندگان
چکیده
The Association for the Advancement of Medical Instrumentation develops voluntary standards for medical devices so that manufacturers might provide information on their product and basic safety and performance criteria that should be considered in qualifying the instrument for clinical use. American national standards are generated through a consensus process by committees consisting of experts in research, development, and design from user, industry, and government communities. Draft standards are made available for public review and may become American national standards after review by the American National Standards Institute. The first American national standard for electronic and automated sphygmomanometers was published in monograph form in 1987. The objective of the revised 1992 standard for electronic and automated sphygmomanometers is to provide updated labeling, safety, and performance requirements that help ensure that consumers and health care professionals are supplied with safe, accurate devices for the indirect measurement of blood pressure, including ambulatory blood pressure recorders. This standard permits validation of the automatic or electronic device by comparison with either direct, intra-arterial blood pressure measurements or the noninvasive cuff/stethoscope technique, based on Korotkoff sounds identified by individuals trained in auscultation. This summary report of the 1992 American national standard for automatic sphygmomanometers provides recommendations for the methods of comparison, statistical analysis of the data, presentation of the results, and criteria for acceptability. Users, researchers, and instrument designers should refer to the American national standard monograph for detailed requirements.
منابع مشابه
Comparison of Various Blood Pressure Measurement Techniques with Standard Office Based Blood Pressure Mesurement
Introduction: In order to control Hypertension, it is necessary to understand the methods of blood pressure measurement. Recent guidelines emphasize on employing appropriate blood pressure measurement techniques and white coat hypertension. Definition and methods of blood pressure measurement have changed in the American guideline based on SPRINT trial (Systolic Blood Pressure Intervention Tria...
متن کاملThe British Hypertension Society protocol for the evaluation of automated and semi-automated blood pressure measuring devices with special reference to ambulatory systems.
With the increasing manufacture of expensive systems for the measurement of ambulatory blood pressure there is a need for potential purchasers to be able to satisfy themselves that the systems have been evaluated according to agreed criteria. The British Hypertension Society has, therefore, drawn up a protocol of requirements for the evaluation of these devices. This protocol incorporates many ...
متن کاملAmbulatory blood pressure monitoring evaluation of a semi-automated device.
The accuracy of a semi-automated ambulatory blood pressure monitoring device (the Instrumedix 'Personal Blood Pressure Transmitter') was assessed in 36 patients undergoing diagnostic cardiac catheterisation. Blood pressure readings measured by the device and by a standard manual sphygmomanometer were compared with simultaneous intra-aortic pressure measured directly via the catheter. No measure...
متن کاملDEVICES AND TECHNOLOGY Evaluation of the Tensioday ambulatory blood pressure monitor according to the protocols of the British Hypertension Society and the Association for the Advancement of Medical Instrumentation
Method The accuracy of calibration of three Tensioday devices was tested before and after the in-use phase when each of three devices was performing 10 24 h sessions of ambulatory monitoring. As all three devices passed these phases, the accuracy of blood pressure measurement was tested in one arbitrarily selected device on 85 subjects for systolic and 85 for diastolic blood pressure values. Th...
متن کاملInaccuracy of seven popular sphygmomanometers for home measurement of blood pressure.
Seven models, available commercially for the self-measurement of blood pressure, were subjected to a validation procedure in which three devices of each model were tested by observers who were trained to a high standard of accuracy. The models were the Omron HEM-400C, the Philips HP5308, the Healthcheck 'Cuffless' CX-5 060020, the Nissei Analogue Monitor, the Philips HP5306/B, the Systema Dr MI...