Diagnostic Accuracy of Charge-coupled Device Sensor and Photostimulable Phosphor Plate Receptor in the Detection of External Root Resorption In Vitro
نویسندگان
چکیده
Background and aims. Early diagnosis of external root resorption is important for accurate treatment. The purpose of this study was to compare the efficacy of a charge-coupled device (CCD) sensor and a photostimulable phosphor (PSP) plate receptor in the diagnosis of artificial external root resorption. Materials and methods. In this diagnostic in-vitro study, 40 maxillary incisors were mounted in a segment of dry bone and preliminary radiographs were obtained using CCD and PSP sensors. Artificial resorption cavities were produced on the middle-third in half of the samples and on the cervical-third in the other half on the buccal root surfaces. Radiographs were repeated and images were evaluated. Data were statistically analyzed using chi-square and diagnostic tests. Results. There were no significant differences between the two sensors in the sensitivity (p=0.08 and 0.06) and specificity (p=0.13) for the diagnosis of resorption in both root areas. The overall accuracy of CCD was higher than PSP sensor; however, the difference was not statistically significance (p>0.05). Conclusion. CCD and PSP sensors chosen for the present study produced similar results in diagnosing simulated external root resorption.
منابع مشابه
مقایسه سنسورهای دیجیتالی Charge-Coupled Device با Photostimulable Phosphor Storage Plate در تشخیص شکستگی عمودی ریشه در دندانهای اندو شده (مطالعه آزمایشگاهی)
Objective: Vertical root fracture (VRF) is among the most common causes of endodontic treatment failures. This study aims to compare charge-coupled devices (CCD) and photostimulable phosphor plates (PSP) for detection of vertical root fractures in endodontically treated teeth. Methods: In this diagnostic in vitro study, 40 maxillary anterior teeth were selected and after preparation and roo...
متن کاملComparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption
Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...
متن کاملDiagnosis of simulated external root resorption using conventional intraoral film radiography, CCD, PSP, and CBCT: a comparison study.
BACKGROUND Diagnosis of external root resorption (ERR) cavities may be challenging, especially when no clinical signs are seen. Therefore, the aim of this study was to compare the efficacy of conventional intraoral film radiography, charge-coupled device (CCD) detector, photostimulable phosphor plate (PSP) detector, and cone beam computed tomography (CBCT) for the detection of ERR. METHODS Th...
متن کاملتوموگرافی خطی با فیلم و Photostimulable Phosphor Plate در طرح درمان ایمپلنت در مندیبل
Background and Aims: Radiographic examination prior to implant placement is often complemented with tomography for location of vital anatomic structures and evaluation of bone volume. The aim of this study was to evaluate the accuracy of Photostimulable Phosphor Plate system with that of conventional film-screen in mandibular pre-implant linear tomography Materials and Methods: In this test eva...
متن کاملComparison of Accuracy and Observer Agreement in the Detection of Simulated External Root Resorption Using Conventional Digital Radiography and Digitally Filtered Radiography
Introduction: External root resorption is a clinical problem that often cannot be detected clinically. Thus, radiography plays a crucial role in its diagnosis. However, optimal radiographic quality with minimal radiation exposure {2.1 [EN] Verify English word/phrase choice} is an important factor in selecting the appropriate radiographic technique. The aim of this study was the comparison of ac...
متن کامل