Reduction in radiation (fluoroscopy) while maintaining safe placement of pedicle screws during lumbar spine fusion.

نویسندگان

  • Christopher D Chaput
  • Keri George
  • Amer F Samdani
  • John I Williams
  • John Gaughan
  • Randal R Betz
چکیده

STUDY DESIGN Prospective, randomized, controlled study. OBJECTIVE To report the results of using the PediGuard (SpineGuard, Inc., San Francisco, CA), a local electrical conductivity measurement device, to reduce radiation exposure while drilling the pilot hole for pedicle screw placement. SUMMARY OF BACKGROUND DATA Reports of pedicle screw placement in the lumbar spine have shown medial pedicle perforations with nerve root impingement in addition to lateral pedicle and vertebral body perforations that can impinge the nerve root within the psoas. Routine use of fluoroscopy (fluoro) is thought to reduce the risk of perforations but is associated with increased radiation. A new pedicle-drilling device (PediGuard) which uses electrical conductivity differentiation at the tip for assessing bone versus soft tissue, has been developed to improve the safe positioning of pedicle screws. This device not only warns of an impending medial breach but also is the only device available to, in real time, nonradiographically detect a lateral breach. METHODS.: Eighteen patients with a diagnosis of lumbar degenerative spine who had a posterior spinal fusion were enrolled. The average age of the patients was 55 ± 12 years. Postoperative computed tomographic scans were reviewed by an independent reviewer. Screws were considered "in" (<2 mm of breach) or "out" (≥ 2 mm of breach). In a randomized fashion, the surgeon placed a pilot hole either with a standard technique (manual probe) or the PediGuard, and used fluoro for each drilling as a guidance assist as necessary. Electromyographic testing was not done by the surgeon. A total of 78 screws (39 via standard probe and 39 with PediGuard assist) were analyzed. RESULTS There was no significant difference in breach rate of 2 mm or more by either of the 2 methods (P = 1.000), with 1 screw out in each group. Fluoro shots averaged 5.2 (range, 0-15) per screw in the PediGuard group versus 7.5 (range, 2-17) in the standard group (P < 0.001). This represents an average decrease of 2.3 (30%) fluoro shots per screw with the PediGuard. There were 202 total fluoro shots used in the PediGuard group versus 293 in the standard group. CONCLUSION In this prospective, randomized trial of a pedicle drilling device that uses electrical conductivity differentiation at the tip for assessing bone versus soft tissue, the number of fluoro shots was reduced by 30% compared with a standard drilling probe while maintaining a 97.5% accurate, safe screw placement.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy Assessment of Freehand Pedicular Screw Placement

Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...

متن کامل

Accuracy of Percutaneous Pedicle Screw Insertion Technique with Conventional Dual Fluoroscopy Units and a Retrospective Comparative Study Based on Surgeon Experience

Study Design Retrospective comparative study. Objective To evaluate the accuracy of percutaneous pedicle screw (PPS) placement and intraoperative imaging time using dual fluoroscopy units and their differences between surgeons with more versus less experience. Methods One hundred sixty-one patients who underwent lumbar fusion surgery were divided into two groups, A (n = 74) and B (n = 87), base...

متن کامل

Modified Mini-open Transforaminal Lumbar Interbody Fusion

STUDY DESIGN Retrospective case series. OBJECTIVE To describe a modified technique for mini-open transforaminal lumbar interbody fusion (TLIF) that improves visualization for decompression, fusion, and freehand pedicle screw insertion. Accuracy of freehand pedicle screw placement with this technique was assessed. SUMMARY OF BACKGROUND DATA Mini-open TLIF is a minimally invasive technique th...

متن کامل

The placement of lumbar pedicle screws using computerised stereotactic guidance.

Computer-assisted frameless stereotactic image guidance allows precise preoperative planning and intraoperative localisation of the image. It has been developed and tested in the laboratory. We evaluated the efficacy, clinical results and complications of placement of a pedicle screw in the lumbar spine using this technique. A total of 62 patients (28 men, 34 women) had lumbar decompression and...

متن کامل

Fluoroscopy-based navigation system in spine surgery

The variability in width, height, and spatial orientation of a spinal pedicle makes pedicle screw insertion a delicate operation. The aim of the current paper is to describe a computer-assisted surgical navigation system based on fluoroscopic X-ray image calibration and three-dimensional optical localizers in order to reduce radiation exposure while increasing accuracy and reliability of the su...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Spine

دوره 37 21  شماره 

صفحات  -

تاریخ انتشار 2012