The passive leg raising test to guide fluid removal in critically ill patients
نویسندگان
چکیده
BACKGROUND To investigate whether haemodynamic intolerance to fluid removal during intermittent renal replacement therapy (RRT) in critically ill patients can be predicted by a passive leg raising (PLR) test performed before RRT. METHODS We included 39 patients where intermittent RRT with weight loss was decided. Intradialytic hypotension was defined as hypotension requiring a therapeutic intervention, as decided by the physicians in charge. Before RRT, the maximal increase in cardiac index (CI, pulse contour analysis) induced by a PLR test was recorded. RRT was then started. RESULTS Ultrafiltration rate was similar in patients with and without intradialytic hypotension. Thirteen patients presented intradialytic hypotension, while 26 did not. In patients with intradialytic hypotension, it occurred 120 min [interquartile range 60-180 min] after onset of RRT. In the 26 patients without intradialytic hypotension, the PLR test induced no significant change in CI. Conversely, in patients with intradialytic hypotension, PLR significantly increased CI by 15 % [interquartile range 11-36 %]. The PLR-induced increase in CI predicted intradialytic hypotension with an area under the ROC curve of 0.89 (95 % interval confidence 0.75-0.97) (p < 0.05 from 0.50). The best diagnostic threshold was 9 %. The sensitivity was 77 % (95 % confidence interval 46-95 %), the specificity was 96 % (80-100 %), the positive predictive value was 91 % (57-100 %), and the negative predictive value was 89 % (72-98 %). Compared to patients without intolerance to RRT, CI decreased significantly faster in patients with intradialytic hypotension, with a slope difference of -0.17 L/min/m(2)/h. CONCLUSION The presence of preload dependence, as assessed by a positive PLR test before starting RRT with fluid removal, predicts that RRT will induce haemodynamic intolerance.
منابع مشابه
Diagnostic Accuracy of Transthoracic Echocardiography to Predict Fluid Responsiveness by Passive Leg Raising in the Critically Ill: A Meta-Analysis
Background: Hemodynamic instability is common in critical patients and not all patients respond to fluid challenge, so we need accurate and rapid hemodynamic techniques to help the clinicians to guide fluid treatment. Numerous hemodynamic techniques have been used to predict fluid responsiveness till now. Transthoracic echocardiography (TTE) appears to have the ability to predict fluid responsi...
متن کاملBioreactance is not reliable for estimating cardiac output and the effects of passive leg raising in critically ill patients.
BACKGROUND Bioreactance estimates cardiac output in a non-invasive way. We evaluated the ability of a bioreactance device (NICOM®) to estimate cardiac index (CI) and to track relative changes induced by volume expansion. METHODS In 48 critically ill patients, we measured CI estimated by the NICOM® device (CINicom) and by transpulmonary thermodilution (CItd, PiCCO2™ device) before and after a ...
متن کاملEchocardiographic Assessment of Preload Responsiveness in Critically Ill Patients
Fluid challenges are considered the cornerstone of resuscitation in critically ill patients. However, clinical studies have demonstrated that only about 50% of hemodynamically unstable patients are volume responsive. Furthermore, increasing evidence suggests that excess fluid resuscitation is associated with increased mortality. It therefore becomes vital to assess a patient's fluid responsiven...
متن کاملPassive Leg-Raising and Prediction of Fluid Responsiveness: Systematic Review.
Fluid boluses are often administered with the aim of improving tissue hypoperfusion in shock. However, only approximately 50% of patients respond to fluid administration with a clinically significant increase in stroke volume. Fluid overload can exacerbate pulmonary edema, precipitate respiratory failure, and prolong mechanical ventilation. Therefore, it is important to predict which hemodynami...
متن کاملBasic concepts of fluid responsiveness
Predicting fluid responsiveness, the response of stroke volume to fluid loading, is a relatively novel concept that aims to optimise circulation, and as such organ perfusion, while avoiding futile and potentially deleterious fluid administrations in critically ill patients. Dynamic parameters have shown to be superior in predicting the response to fluid loading compared with static cardiac fill...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 3 شماره
صفحات -
تاریخ انتشار 2015