Technical Note: Use of a beam width probe in an Aerosol Mass Spectrometer to monitor particle collection efficiency in the field

نویسندگان

  • D. Salcedo
  • T. B. Onasch
  • M. R. Canagaratna
  • K. Dzepina
  • J. A. Huffman
  • J. T. Jayne
  • D. R. Worsnop
  • C. E. Kolb
چکیده

Two Aerodyne Aerosol Mass Spectrometers (QAMS) were deployed in Mexico City, during the Mexico City Metropolitan Area field study (MCMA-2003) from 29 March–4 May 2003 to investigate particle concentrations, sources, and processes. We report the use of a particle beam width probe (BWP) in the field to quantify potential losses of particles due to beam broadening inside the AMS caused by particle shape (nonsphericity) and particle size. Data from this probe show that no significant mass of particles was lost due to excessive beam broadening; i.e. the shapeand size-related collection efficiency (Es) of the AMS during this campaign was approximately one. Comparison of the BWP data from MCMA-2003 with other campaigns shows that the same conclusion holds for several other urban, rural and remotes sites. This means that the aerodynamic lens in the AMS is capable of efficiently focusing ambient particles into a well defined beam and onto the AMS vaporizer for particles sampled in a wide variety of environments. All the species measured by the AMS during MCMA-2003 have similar attenuation profiles which suggests that the particles that dominate the mass concentration were internally mixed most of the time. Only for the smaller particles (especially below 300 nm), organic and inorganic species show different attenuation versus particle size which is likely due to partial external mixing of these components. Changes observed in the focusing of the particle beam in time can be attributed, in part, to changes in particle shape (i.e. due to relative huCorrespondence to: J. L. Jimenez ([email protected]) midity) and size of the particles sampled. However, the relationships between composition, atmospheric conditions, and particle shape and size appear to be very complex and are not yet completely understood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design , Modeling , Optimization , and Experimental Tests of a Particle Beam Width Probe for the Aerodyne Aerosol

Aerodynamic lens inlets have revolutionized aerosol mass spectrometry by allowing the introduction of a very narrow particle beam into a vacuum chamber for subsequent analysis. The real-time measurement of particle beam width after an aerodynamic lens is of interest for two reasons: (1) it allows a correction to be made to the measured particle concentration if the beam is so broad, due to poor...

متن کامل

Design and Construction of an Aerosol Particle Classification System Based on Electrical Mobility

Introduction: The application of particles’ electrical mobility in the electric field has always been an important concern, as the functional basis of a number of particle measuring and classification instrumentations. The objective of this study was to design and construct an aerosol particles classification system using electrical mobility feature in laboratory scale. Methodology: This labo...

متن کامل

Three-Dimensional Simulation of Airflow and Nano-Particle Beam Focusing in Aerodynamic Lenses(RESEARCH NOTE)

In this paper airflow, nano-and micro-particle motions in an aerodynamic particle beam focusing system consisting of several lenses, a nozzle and the downstream chamber, was studied. A three-dimensional numerical simulation for the system was presented and the compressible airflow and thermal conditions in the aerodynamic lens system were evaluated. Dilute particle concentration was assumed so ...

متن کامل

Design, Modeling, Optimization, and Experimental Tests of a Particle Beam Width Probe for the Aerodyne Aerosol Mass Spectrometer

J. Alex Huffman,1 John T. Jayne,2 Frank Drewnick,3 Allison C. Aiken,1 Timothy Onasch,2 Douglas R. Worsnop,2 and Jose L. Jimenez1 1Department of Chemistry and Biochemistry, and Cooperative Institute for Research in the Environmental Sciences (CIRES), University of Colorado, Boulder, Colorado, USA 2Aerodyne Research Inc., Billerica, Massachusetts, USA 3Max Planck Institute for Chemistry, Mainz, G...

متن کامل

Characterization of a thermodenuder-particle beam mass spectrometer system for the study of organic aerosol volatility and composition

This paper describes the development and evaluation of a method for measuring the vapor pressure distribution and volatility-dependent mass spectrum of organic aerosol particles using a thermodenuder-particle beam mass spectrometer. The method is well suited for use with the widely used Aerodyne Aerosol Mass Spectrometer (AMS) and other quantitative aerosol mass spectrometers. The data that can...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007