Pulse width, stimulus intensity, electrode placement, and polarity during assessment of neuromuscular block.

نویسندگان

  • S J Brull
  • D G Silverman
چکیده

BACKGROUND Although the intensity of neurostimulation (i.e., charge) is a product of current intensity and pulse duration, the effects of the latter on the amplitude of evoked response and subjective discomfort are unknown. Therefore, the authors investigated the effects of current intensity and pulse width, and their interaction with electrode placement and polarity, on force translation (FTR), accelerography (ACG), and electromyography (EMG) at the adductor pollics muscle. METHODS Ulnar stimulating electrodes were applied in one of two configurations: over the distal forearm and olecranon groove ("A") or 5 cm apart on the distal forearm ("B"). Stimuli for FTR and EMG with current intensities of 20, 40, 60, and 70 mA and pulse widths of 0.05, 0.1, 0.2, and 0.4 msec resulted in 16 different charges. These combinations were delivered in each of four orientations: "A-" ("A" configuration with negative electrode distal); "A+", "B-", and "B+" (n = 64 stimuli). Eight stimulus combinations (n = 32 stimuli) were used for ACG. For each monitoring technique, the effects of current intensity, pulse width, electrode polarity, and placement were analyzed with repeated measures ANOVA. Pain responses were scored on a 0-100-mm verbal analog scale and analyzed with ANOVA and Fisher's exact test. RESULTS The evoked response amplitude varied directly with current intensity and pulse width. In both electrode placement configurations, the response was greater when the negative electrode was distal. The electrode positioning ("A" vs. "B") had less of an impact on evoked responses than did polarity, regardless of monitoring technique. The evoked pain varied directly with the amplitude of evoked neuromuscular response in all electrode position-polarity combinations. CONCLUSIONS The total current charge required for evoking a supramaximal neuromuscular response is much higher than previously appreciated, and electrode polarity is important in attaining a supramaximal plateau. Failure to attain (and maintain) a supramaximal stimulus allows changes in the effectiveness of neurostimulation, thus influencing the magnitude of the evoked neuromuscular response and confounding measurements of neuromuscular block.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of pulse width and electrode placement on the efficacy and cognitive effects of electroconvulsive therapy.

BACKGROUND While electroconvulsive therapy (ECT) in major depression is effective, cognitive effects limit its use. Reducing the width of the electrical pulse and using the right unilateral electrode placement may decrease adverse cognitive effects, while preserving efficacy. METHODS In a double-masked study, we randomly assigned 90 depressed patients to right unilateral ECT at 6 times seizur...

متن کامل

Influence of stimulus pulse width on M-waves, H-reflexes, and torque during tetanic low-intensity neuromuscular stimulation.

Neuromuscular electrical stimulation (NMES) has been shown to generate contractions that include a central recruitment of motoneurons; however, the effect of pulse width on electromyographic (EMG) and torque responses during NMES are not well documented. Soleus EMG and isometric plantarflexion torque were recorded from 14 subjects with NMES delivered to the tibial nerve using 50, 200, 500, and ...

متن کامل

Experimental Investigation of the Pulse and Plasma Flushing Efficiency in Electrical Discharge Machining

This paper presents a study of the relationship between Electrical Discharge Machining (EDM) parameters on the EDM efficiency factors using a full factorial design, based on pulse on-time, duty cycle and tool polarity parameters in EDM machining of AISI H13 tool steel. The results show that, in positive polarity, the plasma flushing efficiency and pulse efficiency increase according to the puls...

متن کامل

• Neuromuscular Electrical Stimulation Enhances Fracture Healing

METHODS: The study protocol was approved and followed by the Institutional Animal Care and Use Committee of the author’s institution. Twentyfour rabbits received unilateral, transverse, mid-tibial, 3-mm gapped osteotomies that were stabilized with double-bar external fixators. With the aim to simulate the venous stasis and soft tissue edema that is common to acute tibial fractures, the left fem...

متن کامل

Experimental Investigation of Surface Roughness and Kerf Width During Machining of Blanking Die Material on Wire Electric Discharge Machine

Wire electric discharge machine (WEDM) is spark erosion in unconventional machining technique to cut hard and the conductive material with a wire as an electrode. The blanking die material SKD 11 is a high carbon and high chromium tool steel with high hardness and high wearing resistance property. This tool steel has broad application in press tools and dies making industries. In this research ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 83 4  شماره 

صفحات  -

تاریخ انتشار 1995