Flow aeration, cavity processes and energy dissipation on flat and pooled stepped spillways for embankments

نویسندگان

  • Philipp Guenther
  • Stefan Felder
  • Hubert Chanson
چکیده

The design floods of several reservoirs were recently re-evaluated and the revised spillway outflow could result in dam overtopping with catastrophic consequences for some embankment structures. Herein a physical study was performed on flat and pooled stepped spillways with a slope typical of embankments (θ = 26.6◦) and four stepped configurations were tested: a stepped spillway with flat horizontal steps, a pooled stepped spillway, and two stepped spillways with in-line and staggered configurations of flat and pooled steps. The focus of the study was on the flow aeration, air–water flow properties, cavity flow processes, and energy dissipation performances. The results demonstrated the strong aeration of the flow for all configurations. On the in-line and staggered configurations of flat and pooled steps, the flow was highly three-dimensional. The residual head and energy dissipation rates at the stepped chute downstream end were calculated based upon the detailed air–water flow properties. The results showed that the residual energy was the lowest for the flat stepped weir. The data for the stepped spillway configuration with in-line and staggered configurations of flat and pooled steps showed large differences in terms of residual head in the transverse direction. Altogether the present results showed that, on a 26.6◦ slope stepped chute, the designs with in-line and staggered configurations of flat and pooled steps did not provide any advantageous performances in terms of energy dissipation and flow aeration, but they were affected by three-dimensional patterns leading to some flow concentration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flat and Pooled Stepped Spillways for Overflow Weirs and Embankments: Cavity Flow Processes, Flow Aeration and Energy Dissipation

For overflow weirs and embankments, the stepped chute profile may increase the rate of energy dissipation on the waterway. Herein four different stepped chute configurations were tested with a focus on the cavity flow processes, flow aeration and energy dissipation performances. Detailed flow visualisations and air-water flow measurements were conducted for all configurations. The results highl...

متن کامل

Effects of Step Pool Porosity upon Flow Aeration and Energy Dissipation on Pooled Stepped Spillways

The hydraulics of stepped spillways with flat steps has been studied for the last three decades, including for embankment dam slopes, but studies of alternative stepped designs are limited. In this study, a pooled stepped spillway was investigated in a relatively large-size facility, and three different pool wall porosities were tested. The flow patterns, the macroand microscopic air-water flow...

متن کامل

Stepped Spillway Performance: Study of the Pressure and Turbulent Kinetic Energy versus Discharge and Slope

In the present study, flow over flat and pooled stepped spillways was simulated three dimensionally. The VOF method and k- ε (RNG) turbulent model was used to simulate the flow over the stepped spillway. The results indicated that the numerical model was acceptably capable of simulating the flow over the pooled and flat stepped spillways for different discharges. Following that, the effect of d...

متن کامل

Aeration, Flow Instabilities, and Residual Energy on Pooled Stepped Spillways of Embankment Dams

Air-water flow experiments were conducted on some flat and pooled stepped spillways with slopes of 8.9° and 26.6° in transition and skimming flows. The study comprised the observations of the flow patterns, characteristic air-water flow properties, and energy dissipation performances. The air-water flow properties showed some differences in terms of interfacial velocity, bubble count rate, and ...

متن کامل

Energy dissipation and air entrainment on stepped spillways with non-uniform cavity sizes

An experimental study was conducted on a large size stepped spillway model with a moderate slope (26.6o) for a range of discharges between 0.020 and 0.237 m/s. In some experiments, the stepped chute was equipped with uniform steps of 5 and 10 cm heights respectively. In addition several non-uniform configurations with combinations of 5 and 10 cm high steps were investigated. For each configurat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013