AIM This in vitro study is an attempt to compare the effectiveness in cleaning oval shaped root canals using Anatomic Endodontic Technology (AET®), ProFile system® and Manual Instrumentation with K-files. METHODOLOGY Sixty oval shaped single rooted maxillary and mandibular premolars with straight canals were divided in to three groups. The root canals were, confirmed as being oval shape by means of radiographs made in a buccolingual and mesiodistal direction. Automated canal preparation was performed using Anatomic Endodontic Technology (group 1) and the ProFile system® (group 2). Manual instrumentation (group 3) was performed with k-files. Irrigation was performed using alternatively 3% NaOCl and 17% EDTA, followed by rinsing with normal saline. The roots were split longitudinally into two halves and examined under a scanning electron microscope. The presence of debris and smear layer was recorded at distances 1, 5 and 10 mm from the working length using a three step scoring scale. Mean scores for debris and smear layer was calculated and statistically analyzed for between and within groups significance, using the Kruskal-Wallis nonparametric ANOVA test and Bonferroni's multiple comparison test. RESULTS At 1, 5 and 10 mm levels the root canals prepared with AET had significantly less surface debris and smear layer on the canal walls as compared to canals prepared with ProFile system® or manual instrumentation. For all three groups significantly lower mean smear layer scores (p < 0.05) were recorded at 5 and 10 mm levels compared with the 1 mm level. Significantly lower mean debris scores (p < 0.05) were also recorded at 5 and 10 mm levels for the AET group whereas no significant differences were found between the three levels for the ProFile system® and manual instrumentation groups. CONCLUSION Although better instrumentation scores were obtained in canals prepared with AET, complete cleanliness was not achieved with any of the techniques and instruments investigated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness in cleaning oval-shaped root canals using Anatomic Endodontic Technology, ProFile and manual instrumentation: a scanning electron microscopic study.

AIM To compare in vitro the cleanliness of root canal walls in oval-shaped root canals following automated or manual instrumentation. METHODOLOGY Forty-five oval-shaped single-rooted maxillary and mandibular premolars with straight canals were divided into three groups of 15. Automated canal preparation was performed using Anatomic Endodontic Technology (AET, group 1) and the ProFile system (...

متن کامل

بررسی کاهش باکتری داخل کانال با سه روش مکانیکی Instrumentation، K- Type دستی، Race و Profile چرخشی

Statement of Problem: Root canal cleaning and elimination of the source of infection are the most important basis and the main requirements for successful root treatment since the main cause of failure in root treatment is the permeation of bacteria or their products into the periapical tissues. Nowadays, the newly designed and prcsented instruments for canal instrumentation can improve root tr...

متن کامل

مقایسه آزمایشگاهی کارایی روشهای چرخشی Profile، Protaper،  Flex Master و دستی NiTi K-File در آماده‌سازی کانال ریشه

Statement of Problem: Root canal cleaning and shaping are important steps in endodontic therapy. In order to develop better techniques, new instruments are constantly designed and delivered to the market.Purpose: The aim of the present study was to compare the effectiveness of one manual with three rotary root canal instrumentations techniques.Materials and Methods: In this in-vitro study, 80 m...

متن کامل

tHe selF ADJustinG File (sAF) systeM: PeRsPeCtives On A new enDODOntiC teCHnique

intRODuCtiOn The self Adjusting File (sAF*) system is a new approach to shaping root canal systems, which does not use solid metal files. (Fig 1). The sAF relies on the gentle abrasive action of a flexible mesh lattice to prepare the root canal walls. The sAF offers: 1) the ability to instrument and prepare complex-shaped root canal anatomies; 2) the capability to provide continuous and efficie...

متن کامل

Comparison of apically extruded debris and instrumentation time using rotary, endodontic handpiece and hand files in primary molar teeth: (In-vitro )

Abstract Background & Aim : This study was aimed to compare the instrumentation time and the amount of debris extruded apically  during root canal preparation using hand files ,Mtwo rotary system and endodontic handpiece  in primary molar teeth. Method & Material : In this experimental study, sixty roots of  primary molars of human teeth were assigned to three groups (for each group, n=20). The...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The journal of contemporary dental practice

دوره 14 4  شماره 

صفحات  -

تاریخ انتشار 2013