Sound spectrographic diagnosis of aortic ball variance.

نویسندگان

  • J C Hylen
  • F E Kloster
  • R H Herr
  • A Starr
  • H E Griswold
چکیده

Abnormalities in the silastic poppets of cardiac valve prostheses have been detected with increasing frequency. Ball variance can cause serious mechanical dysfunction of the prosthesis and can result in sudden death. Contour sound spectrograms were recorded on 12 patients with ball variance confirmed by operation and 25 controls. In ball variance the frequency of the aortic opening sound at the second right intercostal space was decreased, with the peak frequency recorded being below 1,300 cycles/sec in 11 of the 12 patients. The peak frequency was greater than 1,300 cycles/sec in 24 of the 25 control patients. The remaining patient had peak frequencies in both the normal and abnormal range. The diagnosis of aortic ball variance in patients with triple valve replacement remains difficult because of the nearly synchronous tricuspid closing and aortic opening sounds. The sound spectrographic findings have been the most reliable objective evidence of ball variance in patients with Starr-Edwards aortic prostheses of the Model 1000 series.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Phonocardiographic diagnosis of aortic ball variance.

Fatty infiltration causing changes in the silastic poppet of the Model 1000 series Starr-Edwards aortic valve prostheses (ball variance) has been detected with increasing frequency and can result in sudden death. Phonocardiograms were recorded on 12 patients with ball variance confirmed by operation and of 31 controls. Ten of the 12 patients with ball variance were distinguished from the contro...

متن کامل

Traumatic hemolysis with hemoglobinuria due to ball variance.

P OSTIMPLANTATION ALTERATION of the physicochemical properties of the silastic poppet ( ball variance ) has been reported in some patients with aortic ball valve prostheses.12 Clinical recognition of this situation is difficult, and the diagnosis is usually made at autopsy. This report concerns a patient with ball variance manifested primarily by traumatic intravascular hemolysis and hemoglobin...

متن کامل

L-Ball: Designing A Novel Sports Electronic Audio Ball for Visual Impairment Student

Background. A field study conducted by researchers found the balls used by visual impairment students at school basically used the sound by a small bell inside the ball. However, the sound emitted from the ball is very limited, the ball will sound when it is moved. This makes it difficult for students with visual impairments to find a missing ball that not emitted makes a sound. Objectives. A ...

متن کامل

Sound spectroanalytic diagnosis of malfunctioning prosthetic heart valve.

Sound spectroanalysis was carried out for diagnosis of malfunctioning prosthetic heart valves in 50 cases, which consisted of 31 mitral, 14 aortic, 4 mitral+aortic and 1 tricuspid valve replacements with the age ranging from 17 to 57 years. Types of prosthetic valves used in this series were Starr-Edwards silicon ball valves, metal ball valves, disc valves, Kay-Shiley valves, Smeloff-Cutter val...

متن کامل

Malfunction of the Mitral Valve Prosthesis (Cutter-Smeloff)

Three cases of intermittent obstruction of the mitral prosthesis (Cutter-Smeloff) due to ball variance have been reported. The typical findings were marked variation in the arterial pulse and the intensity of the mitral closing sound and intermittent absence of the opening click. The phonocardiography revealed varying intervals from aortic closing sound to the opening click (A2 OC interval). He...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 39 6  شماره 

صفحات  -

تاریخ انتشار 1969