Vision-based self-calibration and control of parallel kinematic mechanisms without proprioceptive sensing

نویسندگان

  • Nicolas Andreff
  • Philippe Martinet
چکیده

This work is a synthesis of our experience over parallel kinematic machine control, which aims at changing the standard conceptual approach to this problem. Indeed, since the task space, the state space and the measurement space can coincide in this class of mechanism, we came to redefine the complete modeling, identification and control methodology. Thus, it is shown in this paper that, generically and with the help of sensor-based control, this methodology does not require any joint measurement, thus opening a path to simplified mechanical design and reducing the number of kinematic parameters to identify. This novel approach was validated on the reference parallel kinematic mechanism (the Gough-Stewart platform) with vision as the exteroceptive sensor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On Vision-based Kinematic Calibration of a Stewart-Gough Platform

In this article, we propose a vision-based kinematic calibration algorithm for Stewart-Gough parallel structures. Information on the position and orientation of the mechanism legs is extracted from the observation of these kinematic elements with a standard camera. No workspace limitation, nor installation of additional proprioceptive sensors are required. The algorithm is composed of two steps...

متن کامل

Optimization of the Kinematic Sensitivity and the Greatest Continuous Circle in the Constant-orientation Workspace of Planar Parallel Mechanisms

This paper presents the results of a comprehensive study on the efficiency of planar parallel mechanisms, considering their kinetostatic performance and also, their workspace. This aim is approached upon proceeding single- and multi-objective optimization procedures. Kinetostatic performances of ten different planar parallel mechanisms are analyzed by resorting to a recent index, kinematic sens...

متن کامل

Optimal pose selection for vision-based kinematic calibration of parallel mechanisms

In this paper, a new pose selection criterion for the kinematic calibration of parallel mechanisms is proposed. It enables one to take into account the measurement noise amplification that may occur for parallel mechanisms, as well as the variation of amplitude and anisotropy of the measuring device accuracy. This new criterion is applied to vision-based calibration of an Orthoglide mechanism, ...

متن کامل

Vision-based kinernatic calibration of a H4 parallel mechanism

In this article, we present the kinematic calibration of a H4 parallel robot using a vision-based measuring device. Calibration is performed according to the inverse kinematic model method, using first the design model then a model developed for calibration purpose. With a precision of the order of magnitude of 0.2mm and 0.03◦, our vision system allowed us to obtain a final positioning accuracy...

متن کامل

Kinematic and Dynamic Analysis of Tripteron, an Over-constrained 3-DOF Translational Parallel Manipulator, Through Newton-Euler Approach

In this research, as the main contribution, a comprehensive study is carried out on the mathematical modeling and analysis of the inverse kinematics and dynamics of an over-constraint three translational degree-of-freedom parallel manipulator. Due to the inconsistency between the number of equations and unknowns, the problem of obtaining the constraint forces and torques of an over-constraint m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Intelligent Service Robotics

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2009