BASIC INVESTIGATION An Alternative Hemostatic Dressing: Comparison of CELOX, HemCon, and QuikClot

نویسندگان

  • Buddy G. Kozen
  • Sara J. Kircher
  • Jose Henao
  • Fermin S. Godinez
  • Andrew S. Johnson
چکیده

Objectives: Uncontrolled hemorrhage remains a leading cause of traumatic death. Several topical adjunct agents have been shown to be effective in controlling hemorrhage, and two, chitosan wafer dressing (HemCon [HC]) and zeolite powder dressing (QuikClot [QC]), are being utilized regularly on the battlefield. However, recent literature reviews have concluded that no ideal topical agent exists. The authors compared a new chitosan granule dressing (CELOX [CX]) to HC, QC and standard dressing in a lethal hemorrhagic groin injury. Methods: A complex groin injury with transection of the femoral vessels and 3 minutes of uncontrolled hemorrhage was created in 48 swine. The animals were then randomized to four treatment groups (12 animals each). Group 1 included standard gauze dressing (SD); Group 2, CX; Group 3, HC; and Group 4, QC. Each agent was applied with 5 minutes of manual pressure followed by a standard field compression dressing. Hetastarch (500 mL) was infused over 30 minutes. Hemodynamic parameters were recorded over 180 minutes. Primary endpoints included rebleed and death. Results: CX reduced rebleeding to 0% (p < 0.001), HC to 33% (95% CI = 19.7% to 46.3%, p = 0.038), and QC to 8% (95% CI = 3.3% to 15.7%, p = 0.001), compared to 83% (95% CI = 72.4% to 93.6%) for SD. CX improved survival to 100% compared to SD at 50% (95% CI = 35.9% to 64.2%, p = 0.018). Survival for HC (67%) (95% CI = 53.7% to 80.3%) and QC (92%; 95% CI = 84.3% to 99.7%) did not differ from

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An alternative hemostatic dressing: comparison of CELOX, HemCon, and QuikClot.

OBJECTIVES Uncontrolled hemorrhage remains a leading cause of traumatic death. Several topical adjunct agents have been shown to be effective in controlling hemorrhage, and two, chitosan wafer dressing (HemCon [HC]) and zeolite powder dressing (QuikClot [QC]), are being utilized regularly on the battlefield. However, recent literature reviews have concluded that no ideal topical agent exists. T...

متن کامل

Comparative testing of new hemostatic agents in a swine model of extremity arterial and venous hemorrhage.

OBJECTIVE To compare advanced hemostatic dressings: HemCon (HC), QuikClot ACS+ (advanced clotting sponge, and two granular agents: Celox (CX) and WoundStat (WS), with a standard field dressing in a swine model of extremity hemorrhage. METHODS We randomized 30 animals to treatment with a standard dressing or a hemostatic agent applied to a 2 x 6-mm injury in the femoral artery and vein after 4...

متن کامل

Comparison of Celox Gauze haemostat with kaolin based gauze

Objectives: Uncontrolled hemorrhage remains a leading cause of traumatic death. Several topicaladjunct agents have been shown to be effective in controlling hemorrhage, and two, chitosan waferdressing (HemCon [HC]) and zeolite powder dressing (QuikClot [QC]), are being utilized regularly on thebattlefield. However, recent literature reviews have concluded that no ideal topical agent...

متن کامل

Response of the coagulation system after application of hemostatic dressings in an animal model.

The objective of this study was to determine the response of hemostatic dressings. Coagulation and fibrinolytic systems, red blood cell parameters, platelet and leukocyte counts were evaluated after the application of hemostatic dressings: QuikClot, Chitoauze and Celox gauze. The experiment was performed on ten pigs.

متن کامل

Effect of 24 hour application of three hemostatic dressings to porcine thigh muscles.

The effectiveness of three types of hemostatic dressings, QuikClot Gauze, ChitoGauze PRO and Celox Gauze, was evaluated in nine pigs. The results indicated a strong influence of all examined dressings on porcine femoral muscle tissue evaluated 24 hours after direct contact. A histopathological analysis revealed pathological changes in muscle tissue specimens collected from all the animals.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008