Quantitative assessment of the hemodynamic consequences of aortic regurgitation by means of continuous wave Doppler recordings.

نویسندگان

  • P A Grayburn
  • R Handshoe
  • M D Smith
  • M R Harrison
  • A N DeMaria
چکیده

The purpose of this study was to evaluate the ability of continuous wave Doppler ultrasound recordings to reflect the magnitude and hemodynamic effects of aortic regurgitation. Forty-five patients with angiographically proved aortic regurgitation had Doppler studies performed within 24 hours of cardiac catheterization. High quality spectral recordings of the regurgitant jet were obtained in 31 patients, whereas 14 patients exhibited dropout of high velocity signals precluding measurement of maximal velocities. The slope of the peak to end-diastolic velocity decrease measured by Doppler examination was compared with the decay in the aortic to left ventricular diastolic pressure gradient by catheterization and was found to correlate well (r = 0.86). The Doppler velocity decay slope was generally higher in patients with angiographically severe rather than mild or moderate aortic regurgitation, but considerable overlap was present among groups. However, a diastolic velocity decay slope of greater than 3 m/s2 was seen only in those patients with advanced (3 or 4+) aortic regurgitation. Left ventricular end-diastolic pressure was estimated from the Doppler recordings by subtracting the end-diastolic pressure gradient obtained by the modified Bernoulli equation from the cuff diastolic blood pressure. A correlation was observed (r = 0.84) between Doppler and catheterization left ventricular end-diastolic pressure in the 31 patients with high quality spectral data, although the SEE was substantial (5.5 mm Hg). These data demonstrate that continuous wave Doppler recordings of the regurgitant jet can be useful in assessing the angiographic severity and hemodynamics of aortic regurgitation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

Half time of the diastolic aortoventricular pressure difference by continuous wave Doppler ultrasound: a measure of the severity of aortic regurgitation?

Thirty four patients with aortic regurgitation were studied by continuous wave Doppler ultrasound. In 30 of these the regurgitation was graded by cineangiography as mild, moderate, or severe and in four severe regurgitation was confirmed at operation. The half times of the aortoventricular pressure differences obtained with Doppler compared well with those obtained from pressure recordings at c...

متن کامل

Non-invasive grading of aortic regurgitation by Doppler ultrasonography.

Doppler ultrasound without concomitant echocardiographic imaging was used to grade isolated aortic regurgitation in 21 patients. The severity of aortic regurgitation was subsequently graded (from 0 to IV) angiographically. A 2 MHz continuous wave Doppler transducer was placed over the apex of the heart and the beam was aimed parallel to the mitral flow by means of acoustic guidance. Mitral pres...

متن کامل

Colour flow Doppler mapping in the assessment of prosthetic valve regurgitation.

Two hundred Carpentier-Edwards, Björk-Shiley, and Starr-Edwards prostheses in 173 patients were examined. Sixteen (16%) in the aortic and 24 (25%) in the mitral position were associated with clinical signs of regurgitation. A phased array system (Hewlett-Packard A77020A) with a 2.5 MHz duplex and 1.9 MHz continuous wave transducer was used. Colour flow mapping showed trivial transvalvar regurgi...

متن کامل

MITRAL REGURGITATION Quantitation of mitral regurgitation by Doppler echocardiography

The evaluation and care of patients with mitral regurgitation would be facilitated by an easy, reproducible and noninvasive method that could quantitate the hemodynamic burden. In this study, we describe a new Doppler echocardiographic method that measures the regurgitant fraction and we compare it with angiographic and scintigraphic methods. A total of 27 patients with mitral regurgitation wer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 10 1  شماره 

صفحات  -

تاریخ انتشار 1987