Ocular biomechanical measurements on post-keratoplasty corneas using a Scheimpflug-based noncontact device.
نویسندگان
چکیده
AIM To analyse ocular biomechanical properties, central corneal thickness (CCT) and intraocular pressure (IOP) in post-keratoplasty eyes, as compared to normal subjects, with a new Scheimpflug-based technology. Moreover, biomechanical data were correlated with the size and age of the donor and recipient corneas. METHODS Measurements were conducted on 46 eyes of 46 healthy patients without any corneal pathology (age: 53.83±20.8y) and 30 eyes of 28 patients after penetrating keratoplasty (age: 49.43±21.34y). Ten biomechanical parameters, the CCT and IOP were recorded by corneal visualization scheimpflug technology (CorVis ST) using high-speed Scheimpflug imaging. Keratometry values were also recorded using Pentacam HR system. Scheimpflug measurements were performed after 43.41±40.17mo (range: 11-128mo) after the keratoplasty and after 7.64±2.34mo (range: 5-14mo) of suture removal. RESULTS Regarding the device-specific biomechanical parameters, the highest concavity time and radius values showed a significant decrease between these two groups (P=0.01 and P<0.001). None of other biomechanical parameters disclosed a significant difference. The CCT showed a significant difference between post-keratoplasty eyes as compared to normal subjects (P=0.003) using the CorVis ST device. The IOP was within the normal range in both groups (P=0.84). There were no significant relationships between the keratometric data, the size of the donor and recipient, age of the donor and recipient and biomechanical properties obtained by CorVis ST. CONCLUSION The ocular biomechanics remain stable after penetrating keratoplasty according to the CorVis ST measurements. Only two from the ten device-specific parameters have importance in the follow-up period after penetrating keratoplasty.
منابع مشابه
Corneal biomechanical data and biometric parameters measured with Scheimpflug-based devices on normal corneas.
AIM To analyze the correlations between ocular biomechanical and biometric data of the eye, measured by Scheimpflug-based devices on healthy subjects. METHODS Three consecutive measurements were carried out using the corneal visualization Scheimpflug technology (CorVis ST) device on healthy eyes and the 10 device-specific parameters were recorded. Pentacam HR-derived parameters (corneal curva...
متن کاملEffect of Ocular Biomechanics on Intraocular Pressure Measurement in Mucopolysaccharidosis I-S (Scheie’s Syndrome)
Purpose: To study the effect of biomechanical properties of the cornea on the intraocular pressure in eyes affected with Mucopolysaccharidosis type I-S (Scheie's syndrome). Methods: Four eyes of two patients in their mid-fifties diagnosed with Scheie's syndrome were investigated for corneal biomechanical properties. The corneal biomechanical profile was assessed by the use of Ocular response an...
متن کاملComparison of central corneal thickness with four noncontact devices: An agreement analysis of swept-source technology
PURPOSE The purpose of this study was to compare the central corneal thickness (CCT) measurements of four noncontact devices in healthy eyes. MATERIALS AND METHODS In a sample of 45 healthy controls, CCT was measured using an optical biometer (IOLMaster 700) based on swept-source optical coherence tomography (SS-OCT), high-resolution rotating Scheimpflug camera system (Pentacam HR), spectral-...
متن کاملChanges in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology tonometer (CST) in the early phase after small incision lenticule extraction (SMILE)
BACKGROUND Corneal biomechanical properties are always compromised after corneal refractive surgeries thus leading to underestimated intraocular pressure (IOP) that complicates the management of IOP. We investigated the changes in postoperative baseline of IOP values measured with noncontact tonometer (NCT), ocular response analyzer (ORA) and corvis scheimpflug technology (CST) in the early pha...
متن کاملBiomechanical Measurement of Rabbit Cornea by a Modified Scheimpflug Device
Purpose. To explore the probability and variation in biomechanical measurements of rabbit cornea by a modified Scheimpflug device. Methods. A modified Scheimpflug device was developed by imaging anterior segment of the model imitating the intact eye at various posterior pressures. The eight isolated rabbit corneas were mounted on the Barron artificial chamber and images of the anterior segment ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- International journal of ophthalmology
دوره 9 2 شماره
صفحات -
تاریخ انتشار 2016