In vivo intrauterine sound pressure and temperature measurements during magnetic resonance imaging (1.5 T) in pregnant ewes.
نویسندگان
چکیده
OBJECTIVE To investigate the influence of several magnetic resonance imaging (MRI) sequences on amniotic fluid temperature and intrauterine sound pressure. MATERIAL AND METHODS Temperature and sound pressure measurements during MRI (1.5 T) in pregnant ewes were done. Linear levels and third octave band spectra were compared. RESULTS No significant changes in the temperature of amniotic fluid were observed. Intrauterine summation levels reached peak levels up to 103.0 dB(A) before starting the MRI sequence and levels up to 116.0 dB(A) during a real-time sequence. Evaluating the octave band spectra, peak levels did not exceed 100.0 dB(L). CONCLUSIONS Our delimited data revealed no harm for the fetus by an increase in amniotic fluid temperature or hazards for the fetal auditory system by different MRI sequences.
منابع مشابه
Magnetic resonance imaging of feline eye
The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...
متن کاملDNA Damages on Blood Cells After Cardiac Magnetic Resonance Imaging
Introduction: Along with the increased use of cardiac imaging at clinics there is increased attention to the potential risks related to the methods used like magnetic resonance (MR) and it cannot be ruled out that MR can alter DNA structure. The aim of this review is to assess the impact of routine cardiac magnetic resonance (CMR) scanning on DNA damages in human T lymphocytes....
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملSexual Dimorphism in Volume of the Cerebral Hemispheres and Lateral Ventricles in Schizophrenia Using Magnetic Resonance Imaging
Purpose: This study is designed to determine the sexual dimorphism pattern in volume of the cerebral hemispheres and lateral ventricles in schizophrenia using magnetic resonance imaging (MRI) and to compare it with normal sexual dimorphism pattern in healthy brains. Materials and Methods: This study is performed on 29 healthy volunteers (21 males, 8 females) and 29 patients suffered from schiz...
متن کاملEffect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Fetal diagnosis and therapy
دوره 24 3 شماره
صفحات -
تاریخ انتشار 2008