During the winter of 1975-1976, snowfall from the plumes of large natural-draft cooling towers of power plants has been observed. Snow accumulations up to 2.5 centimeters have been found on the ground at extended distances from the cooling towers, and visibility has been restricted to less than 1600 meters in the tower plume near ground level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comprehensive Approach to an Optimum Design and Simulation Model of a Mechanical Draft Wet Cooling Tower

The present paper describes the designing of a thermally and economically optimum mechanical draft counter-flow wet cooling tower. The design model allows the use of a variety of packing materials in the cooling tower toward optimizing heat transfer. Once the optimum packing type is chosen, a compact cooling tower with low fan power consumption is modelled within the known design variables....

متن کامل

Feasibility Study of the Thermal Performance Improvement of Natural Draft Dry Cooling Towers Due to Flue Gas Injection

In steam power plants, any improvement in the cooling towers thermal performance will cause the condenser's temperature to decrease; which in turn enhances the power plant's efficiency. Due to water shortage, many power plants all around the world rely on natural draft dry cooling towers (Heller type). In these cooling towers, condenser's exit hot water is pumped to vertical or horizontal finne...

متن کامل

بهینه سازی تک معیاره و چند معیاره برج خنک کن خشک هلر در نیروگاه‌های سیکل ترکیبی با استفاده از الگوریتم ژنتیک

In this paper the effect of site conditions, which are Altitude, Temperature and Relative Humidity and also Heat Dissipation Capacity are investigated on the optimized design of natural draft dry cooling towers with specific kind of heat exchangers, known as Forgo T60 type. A genetic algorithm program has been developed for optimized design of these cooling towers. Objective function includes b...

متن کامل

Increasing Cooling Towers Heat Capacity by Flue Gas Introduction

In this paper the changes in the heat capacity of cooling towers has been investigated as a result of injecting combustion products of boilers. In the tower, the air is re-heated through mixing with hot flue gas after passing through the heat exchangers. As a result of this process, the draft of the cooling tower is increased. The additional produced draft depends on the ambient temperature and...

متن کامل

Increasing Cooling Towers Heat Capacity by Flue Gas Introduction

In this paper the changes in the heat capacity of cooling towers has been investigated as a result of injecting combustion products of boilers. In the tower, the air is re-heated through mixing with hot flue gas after passing through the heat exchangers. As a result of this process, the draft of the cooling tower is increased. The additional produced draft depends on the ambient temperature and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Science

دوره 193 4259  شماره 

صفحات  -

تاریخ انتشار 1976