The Optical Design of the Human Eye: a Critical Review
نویسنده
چکیده
Cornea, lens and eye models are analyzed and compared to experimental findings to assess properties and eventually unveil optical design principles involved in the structure and function of the optical system of the eye. Models and data often show good match but also some paradoxes. The optical design seems to correspond to a wide angle lens. Compared to conventional optical systems, the eye presents a poor optical quality on axis, but a relatively good quality off-axis, thus yielding higher homogeneity for a wide visual field. This seems the result of an intriguing combination of the symmetry design principle with a total lack of rotational symmetry, decentrations and misalignments of the optical surfaces (J Optom 2009;2:3-18 ©2009 Spanish Council of Optometry)
منابع مشابه
Study of Optical Models Regarding the Human Eye
Introduction: Until now, many models have been presented for optical study of the human eye. In recent years, surgery on the anterior section of the eye (such as cataract and photo-refractive surgery) has increased, so a study on the optics of the eye and evaluation of vision quality has become more important. Material and Methods: In this article, some of these models are considered. They incl...
متن کاملEye-Tracking Method’ Usage for Understanding the Cognitive Processes in Multimedia Learning
Introduction: Designing multimedia learning environments should consist of the evidence-based study and principals about the human learning process. Eye tracking is a way based on the learner processing of learning materials which presented in multimedia learning environments. The aim of the study was to examine the use of the eye-tracking method to investigate the cognitive processes in m...
متن کاملThree Dimensional Ultrasonography of the Eye and Measurement of Optical Nerve Sheet Diameter in Dog
Objective- To determine the possibility of three-dimensional ultrasonography (3DUS) and measurement of optical nerve sheet by this method. Design- Descriptive study. Animals- 10 mixed normal dogs (5males, 5 females), age 1-1.5 year, and weighting 15±5 kg Procedure- 3D ultrasounds of the eyes were evaluated and the normal optical nerves in 3DUS images were measured using Volouson 730 pro....
متن کاملA three-dimensional optical model to describe the optical function of the keratoconus eye
This article has no abstract.
متن کاملBlindness Due to Hyaluronic Acid Filler Injection: A Case Report and Review of Literature
Purpose: To Report a case of blindness due to hyaluronic acid filler injection. Case Report: A 28-year-old female patient was referred to our clinic with complaints of vision loss in the left eye, which occurred one hour after hyaluronic acid filler injection for correction of detachment trough hollowness. In the ophthalmologic examination, relative afferent pupillary defect (RAPD) was positive...
متن کامل