A latex slide agglutination test for rapid detection of antimyeloperoxidase antibody.
نویسندگان
چکیده
AIM To develop and test a new latex slide agglutination test (MPO-LSAT) to detect antimyeloperoxidase (anti-MPO) antibody in serum. METHODS Latex bead coating was adjusted to give maximum sensitivity by attending to latex size, MPO to latex ratio for coupling, ratio of diluted serum to MPO-latex, reaction time and temperature for coupling, and reaction time for agglutination. Inhibition studies were performed using MPO, proteinase 3, bactericidal/permeability increasing protein, and lactoferrin. RESULTS There was very good correlation between this test and the conventional anti-MPO enzyme linked immunosorbent assay (ELISA): 81% of sera positive in the ELISA were positive by MPO-LSAT. MPO-LSAT results correlated better with IgM anti-MPO than with IgG anti-MPO. CONCLUSIONS MPO-LSAT is a simple diagnostic test that is potentially useful in the clinical laboratory as a rapid screening tool for vasculitic diseases.
منابع مشابه
The detection of fibrinogen-fibrin degradation products by means of a new antibody-coated latex particle.
A rapid slide test for the detection of degradation products of fibrinogen/fibrin (FDP) using a new antibody-coated latex particle is described. The latex particle has been specifically coated with antibody to fragments D and E. The latex agglutination test (Thrombo-Wellcotest) has been compared with the tanned red cell haemagglutination inhibition immunoassay (TRCHII) in 143 patients with a va...
متن کاملDevelopment of a slide latex agglutination test for rotavirus antigen detection.
The aim of this study was to optimize the conditions for the passive adsorption of polyclonal antibody onto plain surface polystyrene latex particles and its performance in a slide latex agglutination test for rotavirus antigen detection. Cleaning of latex particles by washing through repetitive centrifuging, decanting and resuspending in distilled water was adequate in removing surfactants fro...
متن کاملA comparison of tests for thyroglobulin antibody.
A comparison is made of tests for thyroglobulin antibody, using gel diffusion, electroprecipitin, bentonite flocculation, tanned red cell agglutination, and latex slide agglutination techniques on sera from cases of Hashimoto's disease and other thyroid disorders. Any increase in gamma globulin was also noted from the serum electrophoretic pattern. The gel diffusion and electroprecipitin tests ...
متن کاملUse of slide latex agglutination test for rapid diagnosis of vaginal candidosis.
A new slide latex agglutination test was compared with microscopy and culture for diagnosing vaginal candidosis in 367 women attending a genitourinary medicine clinic. Vaginal candidosis occurred in 10% of the patients, and 7% had commensal carriage of Candida spp. The slide latex agglutination test was superior to microscopy in immediate diagnosis and was rapid and simple to perform. Of the pa...
متن کاملUse of latex agglutination technique for detecting Legionella pneumophila (serogroup 1) antibodies.
Following the outbreak of Legionnaires' disease in Stafford in 1985, 500 serum samples were submitted to the indirect immunofluorescence antibody test and a latex agglutination. Latex agglutination using ultrasonically disrupted Legionella pneumophila antigens coupled to latex particles, proved a rapid, simple method for detecting circulating antibodies to L pneumophila in a one minute slide la...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 52 10 شماره
صفحات -
تاریخ انتشار 1999