A Universal Engineering Model For Cooling Towers

نویسندگان

  • L. Lu
  • W. Cai
  • Wenjian Cai
چکیده

This paper presents a universal engineering model, which can be used to formulate both counterflow and crossflow cooling towers. By using fundamental laws of mass and energy balance, the effectiveness of heat exchange is approximated by a second order polynomial equation. Gauss-Newton and Levenberg-Marquardt methods are then used to determine the coefficients from manufactures data. Compared with the existing models, the new model has two main advantages: (1) As the engineering model is derived from engineering perspective, it involves fewer input variables and has better description of the cooling tower operation; (2) There is no iterative computation required, this feature is very important for online optimization of cooling tower performance. Although the model is simple, the results are very accurate. Application examples are given to compare the proposed model with commonly used models. NOMENCLATURE Cpw: specific heat of water under constant pressure; Cs: derivative of saturated ha with respect to Tw; c0-c5: curve-fitting constants; dk: search direction of optimization method; Fdata: computation value of εa; ha: enthalpy of air; hs,w: saturation air enthalpy at Tw; hs,wb: saturation air enthalpy at Twb; J(uk): Jacobian matrix of uk; ma: mass flow rate of air; me: mass flow rate of evaporation; ma: mass flow rate of air; mm: mass flow rate of makeup water; mw: mass flow rate of water; NTU: number of transfer units; m: ratio of air to water effective capacitance rate; Qe: heat evaporation rate of loss water; Qrej: heat rejection rate of cooling tower; Tdb: dry-bulb temperature of air; Tm: temperature of makeup water; Tw: temperature of water; Twb: wet-bulb temperature of air; uk: the value of c0-c5 of the kth iteration; εa: heat transfer effectiveness of Braun’s model; ∆h: enthalpy difference with respect to ∆T; ∆T: approach of cooling tower; λk: control coefficients; Subscript i: inlet; o: outlet; INTRODUCTION Cooling towers are commonly used to dissipate heat from heat sources to heat sink (ambient environment). Their applications are typically in Heating Ventilation and Air Conditioning (HVAC) systems and power generators, etc. Heat rejection of cooling towers is accomplished by heat and mass transfer between hot water droplets and ambient air. Although cooling towers are relatively inexpensive and normally consume around ten percent of the whole system energy, their operation has significant effect to the energy consumption of other related subsystems (RMIRA 1995; Michel 1995). Therefore, optimizing cooling tower performance will not only increase the tower efficiencies but also has direct effect to other subsystems. As such, there has been some research interest in this area. Austin (1997) recommended regression methods to create the models of each component in air conditioning systems for predicting and optimizing the system performance. Flake (1997) utilized a different regression technique to determine parameters of the cooling tower model developed by Braun (1989) and to build a predictive model for optimal supervisory control strategies. However, due to the lacking of an effective and precise model for cooling towers, which is essential to estimate and verify the energy savings by different optimization strategies, the research on optimization of cooling tower performance is still in the primary stage. Attempts to develop the cooling tower models have a relative long history, the first such work may trace back to 1925, when Merkel developed a practical model for cooling tower operation, which has been the basis for most modern cooling tower analyses. In his model, the water loss of evaporation is neglected and the Lewis number is assumed to be one in order to simplify the analysis. However, as evaporate water cannot be neglected in cooling tower operation, Merkel’s model is not accurate enough and not suitable for real applications. A more rigorous analysis of a cooling tower model that relaxed Merkel’s restriction was given by Sutherland (1983). In 1989, Braun developed “effectiveness models” for cooling towers, which utilized the assumption of a linearized air saturation enthalpy and the modified definition of number of transfer units. The models were useful for both design and system simulation and has been adopted by the simulation software TRNSYS (SEL 2000). However, Braun’s model needs iterative computation to obtain the output results and is not suitable for online optimization. Bernier (1994) reviewed the heat and mass transfer process in cooling towers at water droplet level and analyzed an idealized spray-type tower in one-dimension, which is useful for cooling tower designers, but no much information is provided to plant operators. Soylemez (1999) presented a quick method for estimating the size and performance of forced draft countercurrent cooling towers and experimental results were used to validate the prediction formulation. Unfortunately, this model also need iterative computation and not suitable for online optimization. In this paper, a universal engineering model, which can be used to formulate both counterflow and crossflow cooling towers, is proposed. Extending the methods provided by Merkel and Braun and using fundamental laws of mass and energy balance, the effectiveness of heat exchange is approximated by a second order polynomial equation. Gauss-Newton and Levenberg-Marquardt methods are then used to determine the coefficients from manufactures data. Compared with the existing models, the new model has two main advantages: (1) As the engineering model is derived from engineering perspective, it involves fewer input variables and has better description of the cooling tower operation; (2) There is no iterative computation required, this feature is very important for online optimization of cooling tower performance. Although the model is simple, the results are very accurate. Application examples are given for both counterflow and crossflow to compare the proposed model with commonly used models. COOLING TOWER MODEL ANALYSIS The mechanism of heat and mass transfer between ambient air and condenser water inside a cooling tower is illustrated in Figure 1. Figure 1. Schematic representation of heat and mass transfer in the cooling tower AIR WATER i a m , i a h , o a h , o a m ,

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Ambient Condition on the Shower Cooling Tower in Four Type of Climates Condition

Water cooling by ambient takes place with two mechanisms of heat and mass transfer. Using packings at wet cooling towers has disadvantages such as obstruction, reduction of life expectancy and production of algae and fungi. In shower cooling towers types of towers packings are completely removed and water intake is in direct contact and heat transfer takes place in two ways of latent and sensib...

متن کامل

Optimal Short-Term Scheduling of Multi-Chiller Plants Considering Energy Requirement of Cooling Towers, Pumps and Chillers

During extremely hot summer days, air conditioning systems are known as major electricity consumers in residential, commercial and industrial sectors. Moreover, high energy requirement of multiple-chiller plants may cause an interconnected power grid be faced with annual on-peak electrical demand, load-generation mismatch, voltage collapse and catastrophic wide area blackout. Therefore, this pa...

متن کامل

Reuse of Refinery Treated Wastewater in Cooling Towers

In this report, experimental investigation of waste water treatment by reverse osmosis to enable its reuse in cooling tower is presented. A polyamide spiral wound RO membrane followed by three filters as RO pretreatment (two activated carbon and one cartridge filter) and samples of Tehran refinery treated waste water have been used. The effect of operating conditions such as pressure differ...

متن کامل

Study of Degradation of Dry Cooling Tower Performance under Wind Conditions and Method for Tower Efficiency Enhancement (RESEARCH NOTE)

Wind affects adversely the cooling tower thermal performance. A field investigation was carried out to study the thermal performance of Heller cooling towers under wind conditions, involving measurement of wind velocity and its direction around the cooling tower, and obtaining water flow rates and temperatures at the cooling tower inlet and outlet. Results show that air suction at the tower top...

متن کامل

Increasing Cooling Towers Heat Capacity by Flue Gas Introduction

In this paper the changes in the heat capacity of cooling towers has been investigated as a result of injecting combustion products of boilers. In the tower, the air is re-heated through mixing with hot flue gas after passing through the heat exchangers. As a result of this process, the draft of the cooling tower is increased. The additional produced draft depends on the ambient temperature and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014