Surface engineering: a low wearing solution for metal-on-metal hip surface replacements.
نویسندگان
چکیده
Increased patient blood and serum levels of Co and Cr and dissemination of metal wear particles throughout organs and tissues are the primary concerns with metal-on-metal surface replacements. Surface engineering, providing a ceramic bearing surface on a metal substrate, could provide a solution. This study investigated thick (>10 microm) arc evaporation plasma vapor deposition chromium nitride (CrN) coated surface replacements in terms of wear, ion levels, and wear particles in a 10 million cycle hip simulator study, compared to a contemporary metal-on-metal surface replacement. The ion levels were measured by inductively coupled plasma mass spectroscopy. The wear particles were imaged by field emission gun scanning electron microscopy. The CrN-coated bearings had 80% lower wear than the MoM controls. The Cr and Co ion levels in the lubricant of the CrN bearings were 73 and 98% lower than in the MoM controls. The wear particles produced were in the nanometer size range and round to oval in morphology. The CrN coating could provide a reduction in the wear and ion release of MoM surface replacements, thereby reducing the perceived risks to the patient associated with these prostheses.
منابع مشابه
Head replacement, head rotation, and surface damage effects on metal-on-metal total hip replacements: a hip simulator study.
The possibility of replacing the femoral head alone, in either solid or articular surface replacement form, during revision operations on metal-on-metal total hip replacements remains an attractive feature of such implants. In the present investigation, laboratory simulator studies of the influence upon volumetric wear of inserting a new femoral head, of introducing some head rotation, and of d...
متن کاملGraphitic tribological layers in metal-on-metal hip replacements.
Arthritis is a leading cause of disability, and when nonoperative methods have failed, a prosthetic implant is a cost-effective and clinically successful treatment. Metal-on-metal replacements are an attractive implant technology, a lower-wear alternative to metal-on-polyethylene devices. Relatively little is known about how sliding occurs in these implants, except that proteins play a critical...
متن کاملThe clinical performance of metal-on-metal as an articulation surface in total hip replacement.
The metal-on-metal articulations in total hip arthroplasty (THA) were widely used between 1960 and 1975. The McKee-Farrar and other first-generation prostheses failed at a high rate because impingement caused early component loosening. The problem of early component loosening was corrected by improved component design and better manufacturing quality. Second-generation metal-on-metal total hip ...
متن کاملPatterns of Risk of Cancer in Patients with Metal-on-Metal Hip Replacements versus Other Bearing Surface Types: A Record Linkage Study between a Prospective Joint Registry and General Practice Electronic Health Records in England
BACKGROUND There are concerns that metal-on-metal hip implants may cause cancer. The objective of this study was to evaluate patterns and timing of risk of cancer in patients with metal-on-metal total hip replacements (THR). METHODS In a linkage study between the English National Joint Registry (NJR) and the Clinical Practice Research Datalink (CPRD), we selected all THR surgeries (NJR) betwe...
متن کاملMetal-on-metal joint bearings and hematopoetic malignancy
This is a review of the hip arthroplasty era. We concentrate on new metal bearings, surface replacements, and the lessons not learned, and we highlight recent reports on malignancies and joint implants. A low incidence of blood malignancies has been found in bone marrow taken at prosthetic surgery. The incidence is increased after replacement with knee implants that release very low systemic le...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical materials research. Part B, Applied biomaterials
دوره 90 2 شماره
صفحات -
تاریخ انتشار 2009