Stability-indicating HPLC method for determination of fosamprenavir calcium.
نویسندگان
چکیده
A novel stability-indicating reverse-phase high-performance liquid chromatographic (HPLC) method has been developed for quantitative determination of Fosamprenavir Calcium, HIV-1 protease inhibitor. Chromatographic separation was achieved using an YMC Pack ODS AQ (150 mm × 4.6 mm × 3.0 μm) HPLC column in isocratic mode employing 0.05 M Potassium dihydrogen orthophosphate monohydrate (pH 6.8) buffer and Acetonitrile in the ratio 60:40 (v/v) with a flow rate of 0.8 mL min(-1). Detector wavelength was monitored at 265 nm and column temperature was maintained at 40 °C. Fosamprenavir calcium was exposed to thermal, photolytic, humidity, water, acid, base and oxidative stress conditions. Considerable degradation of the drug substance was found to occur under acid, base and oxidative stress conditions. Peak homogeneity data of Fosamprenavir Calcium obtained by photodiode array detection demonstrated the specificity of the method in the presence of degradants. The degradation products were well resolved from the main peak of Fosamprenavir, indicating that the method is specific and stability-indicating. The HPLC method was validated as per International Conference on Harmonization guidelines with respect to specificity, precision, linearity, accuracy and robustness. Regression analysis showed a correlation coefficient value greater than 0.999. The accuracy of the method was established based on the recovery obtained for Fosamprenavir Calcium.
منابع مشابه
Stability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method
This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...
متن کاملA stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation
The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...
متن کاملA Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms
Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...
متن کاملStability Indicating HPLC Method for the Determination of Fulvestrant in Pharmaceutical Formulation in Comparison with Linear Sweep Voltammetric Method
This paper describes two rapid, sensitive and specific methods for the determination of fulvestrant in pharmaceutical preparations by high performance liquid chromatography (HPLC) and linear sweep voltammetry (LSV). HPLC method was used to study the degradation behaviour. Fulvestrant was subjected to degradation under the conditions of hydrolysis (acid and alkali), oxidation (30% H2O2). The lin...
متن کاملA Stability Indicating HPLC Method for the Determination of Fluvoxamine in Pharmaceutical Dosage Forms
Fluvoxamine maleate is a selective serotonin reuptake inhibitor, which is used for the treatment of different types of depressive disorders. In the present study, a stability indicating HPLC method was developed and validated for the determination of fluvoxamine maleate. The chromatographic separation was carried out using a Nova-Pak CN column and a mixture of K2HPO4 50 mM (pH 7.0) and acetonit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatographic science
دوره 52 8 شماره
صفحات -
تاریخ انتشار 2014