Separation of polyprenyl phosphate oligomerhomologues by reversed-phase ion-pair high-performance liquid chromatography.

نویسندگان

  • Vyacheslav V Kozlov
  • Leonid L Danilov
چکیده

A simple and rapid method of reversed-phase ion-pair high-performance liquid chromatography (HPLC) with UV-detection on a common C(18) column in an isocratic mode with the addition of tetrabutylammonium phosphate for the separation of polyprenyl phosphate oligomerhomologues has been developed. The method was successfully applied to assay the composition of polyprenyl phosphates obtained from polyprenols isolated from mulberry (Morus alba) leaves and fir (Abies sibirica) needles (the active components of veterinary drugs Gamapren and Phosprenyl correspondingly).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ion-pair chromatography of inositol polyphosphates with N-methylimipramine.

A novel counter-ion, N-methylimipramine, was synthesized and utilized in the separation of inositol phosphates by ion-pair chromatography. The structural identity of the counter-ion was documented by nuclear magnetic resonance spectroscopy. This counter-ion was capable of resolving inositol phosphates isocratically by reversed-phase high-performance liquid chromatography. Solvent polarity and i...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Separation of Somatropin and Its Degradation Products by High-Performance Liquid Chromatography Using a Reversed-Phase Polymeric Column

The accurate prediction of protein stability is one of the most challenging goals in protein formulation and delivery. In this study, a gradient RP-HPLC method is described for the separation of human growth hormone (hGH) variants as deamidated and oxidized forms. The methodology employed a polymeric poly (styrene-co-divinylbenzene) column and a 1mL/min flow rate of a linear gradient of 0.1% v/...

متن کامل

Determination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]

Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...

متن کامل

High-performance liquid chromatography of phosphatidic acids and related polar lipids

The retention behavior of phosphatidic acids (PA) and phosphatidic acid methyl esters (PM) was studied by reversed-phase ion-pair high-performance liquid chromatography (HPLC). The HPLC systems consisted of mobile phases of acetonitrile-methanol-water containing tetraalkylammonium phosphates (TAAP) and stationary phases of alkyl-bonded silica and polystyrene--<:1iviny1benzene resins. The lipid ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 28 10  شماره 

صفحات  -

تاریخ انتشار 2012