Potentiometric Electronic Tongue to Resolve Mixtures of Sulfide and Perchlorate Anions
نویسندگان
چکیده
This work describes the use of an array of potentiometric sensors and an artificial neural network response model to determine perchlorate and sulfide ions in polluted waters, by what is known as an electronic tongue. Sensors used have been all-solid-state PVC membrane selective electrodes, where their ionophores were different metal-phtalocyanine complexes with specific and anion generic responses. The study case illustrates the potential use of electronic tongues in the quantification of mixtures when interfering effects need to be counterbalanced: relative errors in determination of individual ions can be decreased typically from 25% to less than 5%, if compared to the use of a single proposed ion-selective electrode.
منابع مشابه
Electronic Tongue for Qualitative Analysis of Aqueous Solutions of Salts Using Thick-film Technology and Metal Electrodes
An electronic tongue for the qualitative analysis of aqueous solutions of salts has been developed. The following set of electrodes was used: RuO2, Ag, and Cu in thick-film technology and Au, Pb, Zn and Ni as small bars of the corresponding metal. The response of the designed “electronic tongue” was tested on a family of samples containing pure salt and complex mixtures. The electrodes were use...
متن کاملAn Ion-selective Electrode for Anion Perchlorate in Thick-film Technology
The ionophore 1,4,7,10,13-penta(n-octyl)-1,4,7,10,13-pentaazacyclopentadecane (L) was used for the development of miniaturised perchlorate-selective electrodes in thickfilm technology. Different PVC membranes containing L and the plasticizers o-nitrophenyl octyl ether (NPOE), dibutyl phthalate (DBP), bis(2-ethylhexyl)sebacate (DOS) and dibutyl sebacate (DBS) were prepared and placed on a graphi...
متن کاملPotentiometric titration of sulphate, sulphite and dithionate mixtures, with use of a lead ion-selective electrode.
Simple methods are described for the analysis of sulphate, sulphite and dithionate mixtures by potentiometric titration with lead perchlorate (and use of a lead ion-selective electrode). The error and precision are both about 2-5% for the sulphate concentration range 3 x 10(-3) -6 x 10(-4)M. The sulphur content in fuels derived from refuse was determined by potentiometric titration after bomb-c...
متن کاملAluminum(III) Porphyrins as Ionophores for Fluoride Selective Polymeric Membrane Electrodes
Aluminum(III) porphyrins are examined as potential fluoride selective ionophores in polymeric membrane type ionselective electrodes. Membranes formulated with Al(III) tetraphenyl (TPP) or octaethyl (OEP) porphyrins are shown to exhibit enhanced potentiometric selectivity for fluoride over more lipophilic anions, including perchlorate and thiocyanate. However, such membrane electrodes display un...
متن کاملSolvent extraction of Gd(III) from perchlorate and nitrate media with mixtures of thenoyltrifluoroacetone and Benzo-15-Crown-5
The extraction of Gadolinium (Gd) from perchlorate and nitrate media in 1,2-dichloroethane(C2H4Cl2), carbon tetrachloride (CCl4) and chloroform (CHCl3) by mixtures of 2-thenoyltrifluoroacetone (HTTA) and a crown ether benzo-15-crown-5 (B15C5) is investigated.The composition of the extracted species is determined as Gd(TTA)3.nB15C5 (n=1 in nitratemedium and n=2 in perchlorate medium). The values...
متن کامل