lmmunoadsorption assay for bone alkaline phosphatase compared with wheat germ agglutinin precipitation assay in serum from (pre)pubertal girls
نویسندگان
چکیده
The performance characteristics of two bone alkaline phosphatase (ALP; EC 3.1.3.1) assays, a wheat germ agglutinin (WGA) precipitation assay and a new immunoadsorption assay (IAA), were compared. The withinand between-run imprecision of the IAA (3.6-4.2% and 3.6-7.7%) was comparable with that of the WGA assay. The mean crossreactivity with liver ALP appeared to be 4% in the WGA assay and 11 % in the IAA. The reference ranges in a group of 155 healthy Caucasian (pre)pubertal schoolgirls were: 149-401 U/L (total ALP, 30 #{176}C), 105-349 U/L (bone ALP, 30 #{176}C, WGA assay), and 58-205 U/L (bone ALP, 25 #{176}C, IAA). Comparison of the WGA assay (x) with the IAA (y) demonstrated a correlation coefficient of 0.95 [Deming regression equation:y = (0.56 ± 0.01)x + (2.0 ± 1.5); S,,1= 5.3 UIL]. Correlation studies of the WGA assay and the IAA results with total ALP demonstrated r = 0.98 and 0.96, respectively.
منابع مشابه
Immunoadsorption assay for bone alkaline phosphatase compared with wheat germ agglutinin precipitation assay in serum from (pre)pubertal girls.
The performance characteristics of two bone alkaline phosphatase (ALP; EC 3.1.3.1) assays, a wheat germ agglutinin (WGA) precipitation assay and a new immunoadsorption assay (IAA), were compared. The within- and between-run imprecision of the IAA (3.6-4.2% and 3.6-7.7%) was comparable with that of the WGA assay. The mean cross-reactivity with liver ALP appeared to be 4% in the WGA assay and 11%...
متن کاملTwo bone alkaline phosphatase assays compared with osteocalcin as a marker of bone formation in healthy elderly women.
Serum bone alkaline phosphatase (ALP; EC 3.1.3.1) was measured with a wheat germ agglutinin (WGA) precipitation assay and with a new IRMA in a group of healthy elderly women. Both assays were correlated with serum total ALP activity and with osteocalcin. The two bone ALP assays have comparable within- and between-run imprecisions (WGA assay within-run CVs 2.6-5.4% and between-run, 4.0-5.1%; IRM...
متن کاملQuantification of skeletal alkaline phosphatase in osteoporotic serum by wheat germ agglutinin precipitation, heat inactivation, and a two-site immunoradiometric assay.
Three methods for quantifying skeletal alkaline phosphatase (ALP; EC 3.1.3.1) activity/immunoactivity in serum--heat inactivation, wheat germ agglutinin (WGA) precipitation, and an immunoradiometric assay--were tested for recovery and specificity and applied to 81 sera collected from 14 postmenopausal osteoporotic subjects. The heat-inactivation and WGA precipitation assays showed relative reco...
متن کاملMonoclonal antibody assay for measuring bone-specific alkaline phosphatase activity in serum.
Alkaline phosphatase (ALP) is present in human serum in the form of several isoenzymes. The two major circulating ALP isoenzymes, bone and liver, are difficult to distinguish because they are the products of a single gene and differ only by posttranslational glycosylation. Quantitative measurement of bone ALP (BAP) activity in serum can provide an index for the rate of bone formation. Furthermo...
متن کاملWheat-germ agglutinin method for measuring bone and liver isoenzymes of alkaline phosphatase assessed in postmenopausal osteoporosis.
In the method of Rosalki and Foo (Clin Chem 1984;30:1182-6) bone and liver isoenzymes of alkaline phosphatase (EC 3.1.3.1) are quantified by using wheat-germ agglutinin (WGA). I suggest standardizing the procedure by using a WGA concentration that precipitates half of the alkaline phosphatase activity of serum pooled from an equal number of healthy women and men. By applying knowledge of the pr...
متن کامل